Your browser doesn't support javascript.
loading
Imaging evaluation using computed tomography after ascending aortic graft repair.
Raju, Sreenivasa Narayana; Shaw, Manish; Pandey, Niraj Nirmal; Sharma, Arun; Kumar, Sanjeev.
Afiliação
  • Raju SN; Department of Cardiovascular Radiology and Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India.
  • Shaw M; Department of Cardiovascular Radiology and Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India.
  • Pandey NN; Department of Cardiovascular Radiology and Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India.
  • Sharma A; Department of Cardiovascular Radiology and Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India.
  • Kumar S; Department of Cardiovascular Radiology and Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India.
Asian Cardiovasc Thorac Ann ; 29(2): 132-142, 2021 Feb.
Article em En | MEDLINE | ID: mdl-32957798
Prosthetic aortic graft repair is employed in the management of various conditions such as annuloaortic ectasia, ascending aortic aneurysm, type A aortic dissection, and aortic root abscess. Correct interpretation of post-surgical prosthetic graft complications requires familiarity with the expected normal cross-sectional imaging appearance as well knowledge of additional surgical materials used in the repair, which could influence the imaging appearance. Multiple life-threatening complications of a prosthetic ascending aortic graft can be seen in the aorta and vicinity of the operative field. Complications can arise from involvement of the prosthetic aortic graft per se or secondary involvement of the coronary arteries, mediastinum, and sternotomy site. The optimal imaging protocol using multidetector computed tomography allows accurate interpretation of the expected benign postoperative changes as well as complications associated with the prosthetic graft, and differentiation of true complications from their mimickers. This review focuses on the normal imaging appearance of a prosthetic aortic graft on multidetector computed tomography, and imaging evaluation of multiple post-surgical complications that could arise after repair of the ascending aorta and the aortic valve.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças da Aorta / Valva Aórtica / Complicações Pós-Operatórias / Aortografia / Implante de Prótese de Valva Cardíaca / Implante de Prótese Vascular / Tomografia Computadorizada Multidetectores / Angiografia por Tomografia Computadorizada / Doenças das Valvas Cardíacas Tipo de estudo: Diagnostic_studies / Etiology_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Asian Cardiovasc Thorac Ann Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças da Aorta / Valva Aórtica / Complicações Pós-Operatórias / Aortografia / Implante de Prótese de Valva Cardíaca / Implante de Prótese Vascular / Tomografia Computadorizada Multidetectores / Angiografia por Tomografia Computadorizada / Doenças das Valvas Cardíacas Tipo de estudo: Diagnostic_studies / Etiology_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Asian Cardiovasc Thorac Ann Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Índia