Your browser doesn't support javascript.
loading
Development of a personal passive air sampler for estimating exposure to effective chlorine while using chlorine-based disinfectants.
Ha, Yeonjeong; Kim, Yoonsub; Song, Eugene; Yoo, Hyun Jung; Kwon, Jung-Hwan.
Afiliação
  • Ha Y; Division of Environmental Science and Ecological Engineering, Korea University, Seoul, Republic of Korea.
  • Kim Y; Division of Environmental Science and Ecological Engineering, Korea University, Seoul, Republic of Korea.
  • Song E; Department of Consumer Science, Chungbuk National University, Cheongju, Republic of Korea.
  • Yoo HJ; Department of Consumer Science, Chungbuk National University, Cheongju, Republic of Korea.
  • Kwon JH; Division of Environmental Science and Ecological Engineering, Korea University, Seoul, Republic of Korea.
Indoor Air ; 31(2): 557-565, 2021 03.
Article em En | MEDLINE | ID: mdl-32978992
ABSTRACT
With an increasing use of indoor disinfectants such as chlorine (Cl2 ) and hypochlorous acid, a convenient sampler for estimating exposure to oxidants, such as effective chlorine, is necessary. Here, we developed a personal passive air sampler (PPAS) composed of a redox dye, o-dianisidine, in a polydimethylsiloxane (PDMS) sheet. o-Dianisidine readily reacts with gaseous oxidants generated by bleach usage, and its color changes as the reaction progresses; hence, personal exposure to effective chlorine could be easily detected by the naked eye, while cumulative exposure could be determined by measuring concentrations of o-dianisidine reacting with it. The PPAS was calibrated, and a sampling rate of 0.00253 m3 /h was obtained using a small test chamber. The PPAS was tested with the help of ten volunteers whose personal exposure to Cl2 -equivalent gas was estimated after bathrooms were cleaned using spray and liquid-type household disinfection products, and the accumulated exposure-gas concentrations ranged from 69 to 408 ppbv and 148 to 435 ppbv, respectively. These PPAS-derived exposure concentrations were approximately two orders lower than those estimated using ConsExpo, suggesting a significant overestimation by prevailing screening models, possibly due to the ignorance of transformation reactions.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cloro / Monitoramento Ambiental / Poluição do Ar em Ambientes Fechados / Exposição por Inalação / Desinfetantes Limite: Humans Idioma: En Revista: Indoor Air Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cloro / Monitoramento Ambiental / Poluição do Ar em Ambientes Fechados / Exposição por Inalação / Desinfetantes Limite: Humans Idioma: En Revista: Indoor Air Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2021 Tipo de documento: Article