Your browser doesn't support javascript.
loading
The SIOP-Renal Tumour Study Group consensus statement on flank target volume delineation for highly conformal radiotherapy.
Janssens, Geert O; Melchior, Patrick; Mul, Joeri; Saunders, Daniel; Bolle, Stephanie; Cameron, Alison L; Claude, Line; Gurtner, Kristin; van de Ven, Kees P; van Grotel, Martine; Harrabi, Semi; Lassen-Ramshad, Yasmin; Lavan, Naomi; Magelssen, Henriette; Muracciole, Xavier; Boterberg, Tom; Mandeville, Henry; Godzinski, Jan; Graf, Norbert; van den Heuvel-Eibrink, Marry M; Rübe, Christian.
Afiliação
  • Janssens GO; Department of Radiation Oncology, University Medical Centre Utrecht, Utrecht, Netherlands; Princess Máxima Centre for Pediatric Oncology, Utrecht, Netherlands. Electronic address: g.o.r.janssens@umcutrecht.nl.
  • Melchior P; Department of Radiation Oncology, Saarland University Hospital, Homburg, Germany.
  • Mul J; Princess Máxima Centre for Pediatric Oncology, Utrecht, Netherlands.
  • Saunders D; Department of Clinical Oncology, The Christie Hospital, Manchester, United Kingdom.
  • Bolle S; Department of Radiation Oncology, Institut Gustave Roussy, Villejuif, France.
  • Cameron AL; Bristol Cancer Institute, University Hospital Bristol, Bristol, United Kingdom.
  • Claude L; Department of Radiation Oncology, Centre Léon Bérard, Lyon, France.
  • Gurtner K; Department of Radiation Oncology, University Hospital Carl Gustav Carus, Dresden, Germany.
  • van de Ven KP; Princess Máxima Centre for Pediatric Oncology, Utrecht, Netherlands.
  • van Grotel M; Princess Máxima Centre for Pediatric Oncology, Utrecht, Netherlands.
  • Harrabi S; Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.
  • Lassen-Ramshad Y; Department of Clinical Oncology, Aarhus University Hospital, Aarhus, Denmark.
  • Lavan N; St Luke's Radiation Oncology Network, Dublin, Ireland.
  • Magelssen H; Department of Oncology, Oslo University Hospital, Oslo, Norway.
  • Muracciole X; Department of Radiation Oncology, Assistance Publique des Hopitaux de Marseille, Marseille, France.
  • Boterberg T; Department of Radiation Oncology, Ghent University Hospital, Ghent, Belgium.
  • Mandeville H; Department of Clinical Oncology, The Royal Marsden NHS Foundation Trust, Sutton, United Kingdom.
  • Godzinski J; Department of Paediatric Surgery, Marciniak Hospital, Wroclaw, Poland; Department of Paediatric Traumatology and Emergency Medicine, Wroclaw Medical University, Wroclaw, Poland.
  • Graf N; Department of Pediatric Oncology, Saarland University Hospital, Homburg, Germany.
  • van den Heuvel-Eibrink MM; Princess Máxima Centre for Pediatric Oncology, Utrecht, Netherlands.
  • Rübe C; Department of Radiation Oncology, Saarland University Hospital, Homburg, Germany.
Lancet Child Adolesc Health ; 4(11): 846-852, 2020 11.
Article em En | MEDLINE | ID: mdl-33068550
ABSTRACT
For decades, radiotherapy with two opposing photon beams has been the standard technique used to cover the flank target volume in paediatric patients with renal tumours. Nowadays, many institutes are implementing advanced radiotherapy techniques that spare healthy tissue. To decrease the radiotherapy dose to healthy structures while preserving oncological efficacy, the conventional approach of flank irradiation has been adapted into a guideline for highly conformal flank target-volume delineation by paediatric radiation oncologists and representatives of the International Society of Paediatric Oncology's Renal Tumour Study Group (SIOP-RTSG) board during four live international consensus meetings. The consensus was refined by delineation exercises and videoconferences by ten collaborating paediatric radiation oncologists. The final guideline includes eight chronological steps to generate the tumour bed and clinical, internal, and planning target volumes, and it describes the optional use of surgical clips to optimise treatment planning. This guideline will be added into the radiotherapy guideline of the UMBRELLA SIOP-RTSG protocol for paediatric renal tumours to improve international consistency of highly conformal flank target-volume delineation.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radioterapia Conformacional / Tratamentos com Preservação do Órgão / Neoplasias Renais Tipo de estudo: Guideline Limite: Child / Humans Idioma: En Revista: Lancet Child Adolesc Health Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radioterapia Conformacional / Tratamentos com Preservação do Órgão / Neoplasias Renais Tipo de estudo: Guideline Limite: Child / Humans Idioma: En Revista: Lancet Child Adolesc Health Ano de publicação: 2020 Tipo de documento: Article