Your browser doesn't support javascript.
loading
Application of triple quadrupole tandem mass spectrometry to the bioanalysis of collision-induced dissociation-resistant cyclic peptides - Ultra-sensitive quantification of the somatostatin-analog pasireotide utilizing UHPLC-MS/MS.
Sauter, Max; Uhl, Philipp; Burhenne, Jürgen; Haefeli, Walter E.
Afiliação
  • Sauter M; Department of Clinical Pharmacology and Pharmacoepidemiology, Heidelberg University Hospital, Im Neuenheimer Feld 410, 69120 Heidelberg, Germany.
  • Uhl P; Department of Clinical Pharmacology and Pharmacoepidemiology, Heidelberg University Hospital, Im Neuenheimer Feld 410, 69120 Heidelberg, Germany.
  • Burhenne J; Department of Clinical Pharmacology and Pharmacoepidemiology, Heidelberg University Hospital, Im Neuenheimer Feld 410, 69120 Heidelberg, Germany. Electronic address: juergen.burhenne@med.uni-heidelberg.de.
  • Haefeli WE; Department of Clinical Pharmacology and Pharmacoepidemiology, Heidelberg University Hospital, Im Neuenheimer Feld 410, 69120 Heidelberg, Germany.
J Pharm Biomed Anal ; 194: 113728, 2021 Feb 05.
Article em En | MEDLINE | ID: mdl-33234413
ABSTRACT
Cyclic peptides are considered collision-induced dissociation (CID)-resistant due to immobile protons, and the necessity of at least two consecutive dissociation reactions to produce fragments with deviating m/z values. Therefore, the bioanalysis of cyclic peptides by tandem mass spectrometry (MS/MS) poses a major challenge, especially on triple quadrupole (TQ) instruments. One of these peptides is the somatostatin analog pasireotide, a cyclic hexapeptide administered to treat Cushing's disease and acromegaly. To support oral formulation development, sub-therapeutic quantification of pasireotide is highly beneficial. Regardless of the considered CID-resistance, we investigated the CID-characteristics of pasireotide and subsequently developed an ultra-sensitive UHPLC-MS/MS assay with a lower limit of quantification (LLOQ) of 5 pg/mL (4.9 pM) when using 100 µL of plasma and validated it according to the guidelines of the FDA and EMA. The achieved sensitivity, which is the highest thus far reported, demonstrates that TQ-MS/MS is a feasible approach to sensitive quantification of cyclic peptides despite their CID-resistance. Pasireotide was fast and efficiently extracted by protein depletion via precipitation using acetonitrile. Correlation coefficients > 0.99 were achieved for all calibration curves with linear regression. Inter-run and intra-run accuracy ranged from 89.4 to 99.3 % with corresponding precision of ≤ 7.5 % in the calibrated range, and from 94.6 to 105.6 % with corresponding precision of ≤ 14.5 % at the LLOQ. Quantification of 10-fold diluted samples showed an accuracy of 90.8 % and corresponding precision of 4.0 %. The assay was applied to the quantification of pasireotide plasma concentrations after intravenous administration to beagle dogs.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeos Cíclicos / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Guideline Limite: Animals Idioma: En Revista: J Pharm Biomed Anal Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeos Cíclicos / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Guideline Limite: Animals Idioma: En Revista: J Pharm Biomed Anal Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Alemanha