Your browser doesn't support javascript.
loading
Quantitative Mass Spectrometry Imaging to Study Drug Distribution in the Intestine Following Oral Dosing.
Huizing, Lennart R S; McDuffie, James; Cuyckens, Filip; van Heerden, Marjolein; Koudriakova, Tatiana; Heeren, Ron M A; Vreeken, Rob J.
Afiliação
  • Huizing LRS; Maastricht MultiModal Molecular Imaging Institute, Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands.
  • McDuffie J; Janssen Research & Development, 3210 Merryfield Row, San Diego, California 92121, United States.
  • Cuyckens F; Janssen Research & Development, Turnhoutseweg 30, 2340 Beerse, Belgium.
  • van Heerden M; Janssen Research & Development, Turnhoutseweg 30, 2340 Beerse, Belgium.
  • Koudriakova T; Janssen Research & Development, 3210 Merryfield Row, San Diego, California 92121, United States.
  • Heeren RMA; Maastricht MultiModal Molecular Imaging Institute, Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands.
  • Vreeken RJ; Maastricht MultiModal Molecular Imaging Institute, Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands.
Anal Chem ; 93(4): 2144-2151, 2021 02 02.
Article em En | MEDLINE | ID: mdl-33470103
ABSTRACT
Local delivery to the lower gut to treat diseases of the colon has become a topic of special attention. Tissue exposure of locally acting agents is not represented by plasma concentrations. Therefore, reliable methods to measure tissue uptake at the primary site of action (e.g., epithelial layer or lamina propria) are vital. This work investigates the suitability of mass spectrometry imaging (MSI) in quantitatively visualizing intestinal transmural drug distribution. Tofacitinib (Tofa), a drug approved for the treatment of several autoimmune diseases, including ulcerative colitis, was selected as a tool compound for feasibility studies. One- and 7-h postdose sections of the ileum, proximal- and distal-colon from rats that received an oral solution of Tofa were subjected to matrix-assisted laser desorption ionization (MALDI)-MSI. A dilution series of individual concentrations sprayed over an entire tissue section allowed for tissue type-specific quantitation. At 1 h (systemic Tmax), the signal was highest in the ileum, whereas at 7 h, the signal was highest in the colon, when the unabsorbed fraction of the compound reached the colon. A combination of three-dimensional (3D) intensity plots and hematoxylin and eosin (H&E) stains showed a visually observable gradual decrease in Tofa concentration from the lumen toward the muscular layer of the proximal colon. The high luminal concentration of Tofa indicated that flushing of the intestines with saline does not result in complete removal of the drug material from the lumen. This could cause an overestimation of drug concentration in gut tissue homogenates by conventional liquid chromatography-mass spectrometry (LC-MS) methods. This study demonstrates the utility of MSI to differentiate between the lumen and intestinal wall layers and enables proper interpretation of tissue distribution data.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Piperidinas / Pirimidinas / Espectrometria de Massas / Imagem Molecular / Intestinos Limite: Animals Idioma: En Revista: Anal Chem Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Piperidinas / Pirimidinas / Espectrometria de Massas / Imagem Molecular / Intestinos Limite: Animals Idioma: En Revista: Anal Chem Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Holanda