Your browser doesn't support javascript.
loading
Development of glycated peptide enzyme sensor based flow injection analysis system for haemoglobin A1c monitoring using quasi-direct electron transfer type engineered fructosyl peptide oxidase.
Hatada, Mika; Saito, Satomi; Yonehara, Satoshi; Tsugawa, Wakako; Asano, Ryutaro; Ikebukuro, Kazunori; Sode, Koji.
Afiliação
  • Hatada M; Department of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo, 184-8588, Japan; Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State Univer
  • Saito S; Department of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo, 184-8588, Japan.
  • Yonehara S; Arkray, Inc., Yousuien-nai, 59 Gansuin-cho, Kamigyo-ku, Kyoto, 602-0008, Japan.
  • Tsugawa W; Department of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo, 184-8588, Japan.
  • Asano R; Department of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo, 184-8588, Japan.
  • Ikebukuro K; Department of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo, 184-8588, Japan.
  • Sode K; Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC27599, USA. Electronic address: ksode@email.unc.edu.
Biosens Bioelectron ; 177: 112984, 2021 Apr 01.
Article em En | MEDLINE | ID: mdl-33477030
ABSTRACT
Haemoglobin A1c (hemoglobin A1c, HbA1c) is an important long-term glycemic control marker for diabetes. The aim of this study was to develop an enzyme flow injection analysis (FIA) system using engineered fructosyl peptide oxidase (FPOx) based on 2.5th generation principle for an HbA1c automated analytical system. FPOx from Phaeosphaeria nodorum (PnFPOx) was engineered by introducing a Lys residue at the R414 position, to be modified with amine reactive phenazine ethosulfate (arPES) in proximity of FAD. The engineered PnFPOx mutant with minimized oxidase activity, N56A/R414K, showed quasi-direct electron transfer (quasi-DET) ability after PES-modification. The FIA system was constructed by employing a PES-modified PnFPOx N56A/R414K and operated at 0 V against Ag/AgCl. The system showed reproducible responses with a linear range of 20-500 µM for both fructosyl valine (FV) and fructosyl valylhistidine (FVH), with sensitivities of 0.49 nA µM-1 and 0.13 nA µM-1, and the detection limits of 1.3 µM and 2.0 µM for FV and FVH, respectively. These results indicate that the enzyme electrochemical FIA system covers the clinical range of HbA1c detection for more 200 consecutive measurements. Protease digested three different levels of HbA1c samples including healthy and diabetic range subjects were also measured with the FIA system. Thus, it will be possible to develop an integrated system consisting of sample pretreatment and sample electrochemical measurement based on an FIA system possessing quasi-DET type PnFPOx.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Análise de Injeção de Fluxo Limite: Humans Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Análise de Injeção de Fluxo Limite: Humans Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2021 Tipo de documento: Article