Your browser doesn't support javascript.
loading
Perforator Detection by Thermographic Imaging Augmented With Tourniquet-Reperfusion: A Modified Approach and Preliminary Report in Distal Lower Leg Reconstruction.
Pan, Jia-Dong; Xu, Heng; Xiao, Dong-Chao; Hacquebord, Jacques Henri; Chang, Shi-Min; Wang, Xin.
Afiliação
  • Xu H; Department of Plastic and Reconstructive Surgery, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Xiao DC; Department of Hand Surgery, Ningbo Sixth Hospital, Ningbo.
  • Hacquebord JH; Department of Orthopedic Surgery, Hansjörg Wyss Department of Plastic Surgery, New York University, New York, USA.
  • Chang SM; From the Department of Orthopedic Surgery, Yangpu Hospital, Tongji University School of Medicine, Shanghai.
  • Wang X; Department of Hand Surgery, Ningbo Sixth Hospital, Ningbo.
Ann Plast Surg ; 87(4): 451-456, 2021 10 01.
Article em En | MEDLINE | ID: mdl-33587459
BACKGROUND: Dynamic infrared thermography provides a new imaging method of perforator detection. This study introduces an augmented technique to improve its accuracy by tourniquet-reperfusion and reports its preliminary use in the distal lower leg reconstruction. METHODS: A tourniquet (450 mm Hg) was applied for 3 minutes on proximal thighs. After the tourniquet release, the rewarming rate and pattern of hotspots were observed by thermography to delineate the location and quality of perforators. The results were compared with those detected by computed tomographic angiography. Clinically, the local transferred posterior tibial artery or peroneal artery propeller perforator flap was performed in 9 patients for the distal lower leg reconstruction. RESULTS: There was a 20- to 140-second "perforator observing window" after the tourniquet release. Tourniquet-reperfusion augmented thermal imaging method (TRATIM) had a sensitivity of 90.3% and a positive predictive value of 93.3%. The TRATIM and computed tomographic angiography had an excellent concordance with a kappa index value of 0.839 (P < 0.001). Based on the TRATIM, 9 propeller perforator flaps were successfully designed and raised for the distal lower leg resurfacing. All flaps survived entirely, except one with size of 1.0 cm × 2.0 cm that had terminal necrosis. CONCLUSIONS: The TRATIM is a quick, easy, cheap, and reliable approach for perforator detection in the lower leg. With the aid of TRATIM, a customized propeller perforator flap could be raised efficiently for the distal lower leg reconstruction.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimentos de Cirurgia Plástica / Retalho Perfurante Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Ann Plast Surg Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimentos de Cirurgia Plástica / Retalho Perfurante Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Ann Plast Surg Ano de publicação: 2021 Tipo de documento: Article