Limitations of Postless Hip Arthroscopy for a Patient with Coxa Profunda: A Case Report.
JBJS Case Connect
; 11(1)2021 03 03.
Article
em En
| MEDLINE
| ID: mdl-33657025
ABSTRACT
CASE A 27-year-old man with coxa profunda and a right acetabular labral tear presented for surgical re-evaluation after a postless arthroscopic labral repair was attempted at an outside institution and aborted because of inadequate distraction during portal placement. Arthroscopic labral repair with a perineal post was subsequently performed without complications. CONCLUSION:
Indications and limitations of postless hip distraction are seldom discussed in the literature. This report examines possible limitations of postless hip distraction for a patient with coxa profunda. Careful radiographic evaluation of hip anatomy may be essential for patients with deep hip sockets to determine the best-suited distraction technique.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Artroscopia
/
Impacto Femoroacetabular
Limite:
Adult
/
Humans
/
Male
Idioma:
En
Revista:
JBJS Case Connect
Ano de publicação:
2021
Tipo de documento:
Article