Your browser doesn't support javascript.
loading
Transient electroretinographic abnormalities that mimic those of KCNV2 retinopathy: a case report.
Kaizuka, Chihiro; Hayashi, Takaaki; Mizobuchi, Kei; Kubota, Masaomi; Ueno, Shinji; Nakano, Tadashi.
Afiliação
  • Kaizuka C; Department of Ophthalmology, Katsushika Medical Center, The Jikei University School of Medicine, 6-41-2 Aoto, Katsushika-ku, Tokyo, 125-8506, Japan.
  • Hayashi T; Department of Ophthalmology, Katsushika Medical Center, The Jikei University School of Medicine, 6-41-2 Aoto, Katsushika-ku, Tokyo, 125-8506, Japan. taka@jikei.ac.jp.
  • Mizobuchi K; Department of Ophthalmology, The Jikei University School of Medicine, Tokyo, 105-8461, Japan.
  • Kubota M; Department of Ophthalmology, Katsushika Medical Center, The Jikei University School of Medicine, 6-41-2 Aoto, Katsushika-ku, Tokyo, 125-8506, Japan.
  • Ueno S; Department of Ophthalmology, Nagoya University Graduate School of Medicine, Aichi, 466-8560, Japan.
  • Nakano T; Department of Ophthalmology, The Jikei University School of Medicine, Tokyo, 105-8461, Japan.
Doc Ophthalmol ; 143(2): 221-228, 2021 10.
Article em En | MEDLINE | ID: mdl-33738644
PURPOSE: The purpose of this report was to describe the case of a 68-year-old male patient with stage IV colon cancer who exhibited electroretinographic abnormalities that are similar to those of KCNV2 retinopathy. METHODS: The patient presenting with photophobia, reduced visual acuity, and poor general conditions, the onset of which occurred ten days before presentation, was examined using fundoscopy, full-field electroretinography, blood tests, and abdominal computed tomography. RESULTS: The patient's decimal best-corrected visual acuity (BCVA) was 0.4 in each eye. Fundoscopy showed bull's eye-like maculopathy in both eyes. Electroretinographic findings were similar to the characteristic findings of KCNV2 retinopathy: Rod electroretinogram showed delayed and preserved b-wave amplitudes; bright-flash electroretinogram showed double troughs of a-waves; b/a ratios shown by bright-flash electroretinogram were higher than those shown by standard-flash electroretinogram; and both cone and 30-Hz flicker electroretinograms showed extinguished responses. His serum potassium level increased to 6.2 mmol/L (normal range 3.6-4.8 mmol/L) owing to hydronephrosis resulting from disseminated carcinoma. After performing an emergency surgery to treat this condition, the serum potassium level immediately decreased to a normal range. Eleven days after presentation, rod and standard/bright-flash electroretinography showed improvement in the implicit time of the rod b-waves and the a-waves. Unexpectedly, the responses recorded by cone and 30-Hz flicker electroretinography became normal. The symptoms and maculopathy disappeared, and his BCVA improved to 1.2. CONCLUSIONS: The abnormal electroretinographic findings might be associated with the transient increase in serum potassium level.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Retinianas / Canais de Potássio de Abertura Dependente da Tensão da Membrana Tipo de estudo: Diagnostic_studies Limite: Aged / Humans / Male Idioma: En Revista: Doc Ophthalmol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Retinianas / Canais de Potássio de Abertura Dependente da Tensão da Membrana Tipo de estudo: Diagnostic_studies Limite: Aged / Humans / Male Idioma: En Revista: Doc Ophthalmol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Japão