Your browser doesn't support javascript.
loading
Reduced acquisition time for thallium myocardial perfusion imaging with large field cadmium-zinc-telluride SPECT/CT cameras: An equivalence study.
Bonnefoy, P B; Janvier, L; Arede, C; Drouet, C; Harami, D; Marque, S; Ahond-Vionnet, R.
Afiliação
  • Bonnefoy PB; Service de Médecine Nucléaire, Hôpital Pierre Bérégovoy, Nevers, France. p.benoit.bonnefoy@chu-st-etienne.fr.
  • Janvier L; Service de Médecine Nucléaire, CHU Saint-Etienne - Hôpital Nord, Saint Etienne, France. p.benoit.bonnefoy@chu-st-etienne.fr.
  • Arede C; Service de Médecine Nucléaire, CHU de Saint-Etienne, 42055, Saint-Étienne, France. p.benoit.bonnefoy@chu-st-etienne.fr.
  • Drouet C; Service de Médecine Nucléaire, Hôpital Pierre Bérégovoy, Nevers, France.
  • Harami D; Service de Médecine Nucléaire, Hôpital Pierre Bérégovoy, Nevers, France.
  • Marque S; Service de Médecine Nucléaire, Hôpital Pierre Bérégovoy, Nevers, France.
  • Ahond-Vionnet R; Service de Médecine Nucléaire, Centre Georges-François Leclerc, Dijon, France.
J Nucl Cardiol ; 29(4): 1933-1941, 2022 08.
Article em En | MEDLINE | ID: mdl-33890184
BACKGROUND: Cadmium-zinc-telluride (CZT) SPECT/CT cameras with large field of view offer a higher sensitivity than conventional Anger cameras. This prospective study aimed to determine the equivalence between a conventional protocol and a reduced acquisition time protocol for 201-Thallium myocardial perfusion imaging (MPI) using a whole-body CZT SPECT camera. METHODS AND RESULTS: Stress MPI was obtained for 103 consecutive patients on a DISCOVERY-CZT camera. Images were anonymized and post-processed to simulate a 25% (D75 dataset) and 50% (D50 dataset) decrease in total recorded counts. Concerning the number of segments displaying a tracer uptake < 70% of maximum intensity per patient, equivalence was demonstrated for both count-reduced datasets with a good inter-observer agreement (between 0.90 and 0.88). When comparing the full-vs-D75 datasets and full-vs-D50 datasets, mean difference was 0.06 segment (CI95: [- 0.15;0.27], P < 0.001) and 0.518 segment (CI95: [0.28;0.76], P < 0.001) respectively. Inter-observer agreement was also moderate to good concerning the number of pathological segments (between 0.6 and 0.7) and excellent for functional parameters. CONCLUSION: Whole-body CZT SPECT/CT cameras allow to reduce 201-Thallium MPI injected activity or acquisition time by 50% with an equivalence in the number of segments displaying a tracer uptake < 70% of maximum intensity and with a good inter-observer agreement.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imagem de Perfusão do Miocárdio Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: J Nucl Cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imagem de Perfusão do Miocárdio Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: J Nucl Cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: França