Measuring steroids from dried blood spots using tandem mass spectrometry to diagnose congenital adrenal hyperplasia.
Qasrawi, Deema O; Boyd, Jessica M; Sadrzadeh, S M H.
Afiliação
  • Qasrawi DO; Segal Cancer Proteomics Centre, Lady Davis Institute for Medical Research, Jewish General Hospital, 3755 Côte Ste-Catherine Road, Montreal, QC, H3T 1E2, Canada; Alberta Precision Laboratories - Calgary and Department of Pathology and Laboratory Medicine, Cumming School of Medicine, University of Calgary, 9-3535 Research Road NW, Calgary, AB T2L 2K8, Canada. Electronic address: deema.qasrawi@ladydavis.ca.
  • Boyd JM; Alberta Precision Laboratories - Calgary and Department of Pathology and Laboratory Medicine, Cumming School of Medicine, University of Calgary, 9-3535 Research Road NW, Calgary, AB T2L 2K8, Canada.
  • Sadrzadeh SMH; Alberta Precision Laboratories - Calgary and Department of Pathology and Laboratory Medicine, Cumming School of Medicine, University of Calgary, 9-3535 Research Road NW, Calgary, AB T2L 2K8, Canada.
Clin Chim Acta ; 520: 202-207, 2021 Sep.
Article em En | MEDLINE | ID: mdl-34097883
BACKGROUND: Congenital adrenal hyperplasia (CAH) is a group of autosomal recessive disorders that occur due to defects in the steroidogenesis pathway. Approximately 90% of CAH cases can be diagnosed by the measurement of serum 17-hydroxyprogesterone alone. However, the quantification of six additional steroids could significantly improve CAH laboratory diagnosis. Using dried blood spot (DBS) as specimen of choice can further improve patient care due to the small sample volume required for CAH diagnosis in neonates. METHODS: An optimized DBS sample preparation method was employed for steroids quantification without the need of derivatization. A LC-MS/MS assay was developed and optimized using a reverse phase-ultra high-pressure liquid chromatography (RP-UHPLC) system combined with triple quadrupole mass spectrometry using positive electrospray ionization mode. RESULTS: The assay was validated according to CLSI analytical guidelines, including lower limit of quantification (LLOQ), linearity, precision, accuracy, carryover, and method comparison. The analytical measuring range of the method for all steroids was 2.5, 5, or 10 ng/ml to 250 ng/ml in DBS, r2 ≥ 0.995. The LLOQ, intra-day and inter-day precision were 0.11-1.8 ng/ml, 1.2-6.4 ng/ml, 1.8-11.5%, and 5.3-13.8%, respectively. CONCLUSIONS: Our LC-MS/MS assay simultaneously detects 7 steroids for the diagnosis of CAH and can be readily implemented in clinical laboratories to provide superior analytical performance over traditional immunoassays.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Hiperplasia Suprarrenal Congênita / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Guideline Limite: Humans / Newborn Idioma: En Revista: Clin Chim Acta Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Hiperplasia Suprarrenal Congênita / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Guideline Limite: Humans / Newborn Idioma: En Revista: Clin Chim Acta Ano de publicação: 2021 Tipo de documento: Article