Cost-effectiveness of implantable cardioverter-defibrillators for primary prevention of sudden cardiac death.
Ribera, Aida; Giménez, Emmanuel; Oristrell, Gerard; Osorio, Dimelza; Marsal, Josep Ramón; García-Pérez, Lidia; Ballesteros, Mónica; Ródenas, Eduard; Belahnech, Yassin; Escalona, Roxana; Rivas, Núria; Roca-Luque, Ivo; Ferreira-González, Ignacio; Espallargues, Mireia.
Afiliação
  • Ribera A; Unidad de Epidemiología Cardiovascular, Servicio de Cardiología, Hospital Universitario Vall d'Hebron, Institut de Recerca Vall d'Hebron (VHIR), Barcelona, Spain; Centro de Investigación en Red de Epidemiología y Salud Pública (CIBERESP), Spain. Electronic address: aida.ribera@vhir.org.
  • Giménez E; Agència de Qualitat i Avaluació Sanitàries de Catalunya (AQuAS), Departament de Salut, Barcelona, Spain.
  • Oristrell G; Servicio de Cardiología, Hospital Universitario Vall d'Hebron, Barcelona, Spain; Centro de Investigación en Red de Enfermedades Cardiovasculares (CIBERCV), Spain.
  • Osorio D; Centro de Investigación en Red de Epidemiología y Salud Pública (CIBERESP), Spain; Unidad de Calidad-Mejora de la Práctica Clínica, Dirección de Procesos y Calidad, Hospital Universitario Vall d'Hebron, Barcelona, Spain.
  • Marsal JR; Unidad de Epidemiología Cardiovascular, Servicio de Cardiología, Hospital Universitario Vall d'Hebron, Institut de Recerca Vall d'Hebron (VHIR), Barcelona, Spain; Centro de Investigación en Red de Epidemiología y Salud Pública (CIBERESP), Spain.
  • García-Pérez L; Servicio de Evaluación del Servicio Canario de la Salud (SESCS), Tenerife, Spain; Red Española de Agencias de Evaluación de Tecnologías Sanitarias y Prestaciones del Sistema Nacional de Salud (RedETS), Spain; Red de Investigación en Servicios de Salud en Enfermedades Crónicas (REDISSEC), Madrid, Spa
  • Ballesteros M; Centro de Investigación en Red de Epidemiología y Salud Pública (CIBERESP), Spain; Unidad de Calidad-Mejora de la Práctica Clínica, Dirección de Procesos y Calidad, Hospital Universitario Vall d'Hebron, Barcelona, Spain.
  • Ródenas E; Servicio de Cardiología, Hospital Universitario Vall d'Hebron, Barcelona, Spain.
  • Belahnech Y; Servicio de Cardiología, Hospital Universitario Vall d'Hebron, Barcelona, Spain.
  • Escalona R; Servicio de Cardiología, Hospital Universitario Vall d'Hebron, Barcelona, Spain.
  • Rivas N; Servicio de Cardiología, Hospital Universitario Vall d'Hebron, Barcelona, Spain.
  • Roca-Luque I; Unidad de Arritmias, Institut Cardiovascular, Hospital Clínic de Barcelona, Barcelona, Spain.
  • Ferreira-González I; Unidad de Epidemiología Cardiovascular, Servicio de Cardiología, Hospital Universitario Vall d'Hebron, Institut de Recerca Vall d'Hebron (VHIR), Barcelona, Spain; Centro de Investigación en Red de Epidemiología y Salud Pública (CIBERESP), Spain; Servicio de Cardiología, Hospital Universitario Vall d
  • Espallargues M; Agència de Qualitat i Avaluació Sanitàries de Catalunya (AQuAS), Departament de Salut, Barcelona, Spain; Red de Investigación en Servicios de Salud en Enfermedades Crónicas (REDISSEC), Madrid, Spain.
Rev Esp Cardiol (Engl Ed) ; 75(1): 12-21, 2022 Jan.
Article em En, Es | MEDLINE | ID: mdl-34099431
ABSTRACT
INTRODUCTION AND

OBJECTIVES:

Implantable cardioverter-defibrillators (ICD) are a cost-effective alternative for secondary prevention of sudden cardiac death, but their efficiency in primary prevention, especially among patients with nonischemic heart disease, is still uncertain.

METHODS:

We performed a cost-effectiveness analysis of ICD plus conventional medical treatment (CMT) vs CMT for primary prevention of cardiac arrhythmias from the perspective of the national health service. We simulated the course of the disease by using Markov models in patients with ischemic and nonischemic heart disease. The parameters of the model were based on the results obtained from a meta-analysis of clinical trials published between 1996 and 2018 comparing ICD plus CMT vs CMT, the safety results of the DANISH trial, and analysis of real-world clinical practice in a tertiary hospital.

RESULTS:

We estimated that ICD reduced the likelihood of all-cause death in patients with ischemic heart disease (HR, 0.70; 95%CI, 0.58-0.85) and in those with nonischemic heart disease (HR, 0.79; 95%CI, 0.66-0.96). The incremental cost-effectiveness ratio (ICER) estimated with probabilistic analysis was €19 171/quality adjusted life year (QALY) in patients with ischemic heart disease and €31 084/QALY in those with nonischemic dilated myocardiopathy overall and €23 230/QALY in patients younger than 68 years.

CONCLUSIONS:

The efficiency of single-lead ICD systems has improved in the last decade, and these devices are cost-effective in patients with ischemic and nonischemic left ventricular dysfunction younger than 68 years, assuming willingness to pay as €25 000/QALY. For older nonischemic patients, the ICER was around €30 000/QALY.