Your browser doesn't support javascript.
loading
Correlation Between QElaXto Techniques and Supersonic Imagine for Liver Stiffness Quantification in Chronic Liver Disease.
Garcovich, Matteo; Faccia, Mariella; Di Stasio, Enrico; Riccardi, Laura; Zocco, Maria A; Ainora, Maria E; Vecchio, Fabio M; Mingrone, Geltrude; Gasbarrini, Antonio; Pompili, Maurizio.
Afiliação
  • Garcovich M; CEMAD Digestive Center, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy.
  • Faccia M; Facoltà di Medicina e Chirurgia, Università Cattolica del Sacro Cuore, Rome, Italy.
  • Di Stasio E; CEMAD Digestive Center, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy.
  • Riccardi L; Facoltà di Medicina e Chirurgia, Università Cattolica del Sacro Cuore, Rome, Italy.
  • Zocco MA; Department of  Laboratory Medicine, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy.
  • Ainora ME; CEMAD Digestive Center, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy.
  • Vecchio FM; Facoltà di Medicina e Chirurgia, Università Cattolica del Sacro Cuore, Rome, Italy.
  • Mingrone G; CEMAD Digestive Center, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy.
  • Gasbarrini A; Facoltà di Medicina e Chirurgia, Università Cattolica del Sacro Cuore, Rome, Italy.
  • Pompili M; CEMAD Digestive Center, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy.
J Ultrasound Med ; 41(4): 877-886, 2022 Apr.
Article em En | MEDLINE | ID: mdl-34170033
ABSTRACT

OBJECTIVES:

Intersystem variability in liver stiffness (LS) quantification with ultrasound shear wave elastography (SWE) precludes direct comparison of results obtained with different equipment. The aim of this study was to investigate the agreement between point-SWE and 2-dimensional-SWE with Esaote-MyLab 9 (p-QElaXto and 2D-QElaXto, respectively) and 2D-SWE with SuperSonic Imagine (SSI) in order to assess specific LS thresholds for fibrosis staging with QElaXto techniques, using SSI as a reference standard.

METHODS:

A total of 235 compensated chronic liver disease (CLD) patients without comorbidities potentially affecting LS were enrolled in the study. Among them, 101 patients underwent also liver biopsy. Agreement between the equipment was assessed with Pearson coefficient and Bland-Altman analysis, while cut-off values were calculated with receiver operating characteristics analysis.

RESULTS:

Correlation between 2D-QElaXto and p-QElaXto with SSI resulted very good (r = 0.898 and r = 0.866), especially in precirrhotic stages, with a mean difference between LS values of -1.3 kPa for 2D-QElaXto and -0.6 kPa for p-QElaXto compared with SSI. Cut-off thresholds for diagnosing fibrosis ≥F2, ≥F3, and F4 in non-HBV-related CLD were, respectively, 5.5, 8.0, and 10.6 kPa for 2D-QElaXto and 6.1, 8.1, and 11.7 kPa for p-QElaXto. All three SWE techniques were effective in differentiating significant fibrosis ≥F2 from mild or absent fibrosis in the subgroup of patients submitted to biopsy and showed good feasibility.

CONCLUSIONS:

Correlation between QElaXto techniques and SSI in LS measurements is very good. Our study identifies for the first time cut-off thresholds for fibrosis staging in non-HBV-related CLD using two QElaXto techniques.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas de Imagem por Elasticidade / Hepatopatias Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Ultrasound Med Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas de Imagem por Elasticidade / Hepatopatias Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Ultrasound Med Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Itália