Prosthesis-Patient Mismatch After Aortic Valve Replacement in the PARTNER 2 Trial and Registry.
Ternacle, Julien; Pibarot, Philippe; Herrmann, Howard C; Kodali, Susheel; Leipsic, Jonathon; Blanke, Philipp; Jaber, Wael; Mack, Michael J; Clavel, Marie-Annick; Salaun, Erwan; Guzzetti, Ezequiel; Annabi, Mohamed-Salah; Bernier, Mathieu; Beaudoin, Jonathan; Khalique, Omar K; Weissman, Neil J; Douglas, Pamela; Bax, Jeroen; Dahou, Abdellaziz; Xu, Ke; Alu, Maria; Rogers, Erin; Leon, Martin; Thourani, Vinod H; Abbas, Amr E; Hahn, Rebecca T.
Afiliação
  • Ternacle J; Québec Heart and Lung Institute, Université Laval, Quebec City, Quebec, Canada.
  • Pibarot P; Québec Heart and Lung Institute, Université Laval, Quebec City, Quebec, Canada. Electronic address: philippe.pibarot@med.ulaval.ca.
  • Herrmann HC; Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Kodali S; Columbia University Medical Center/NewYork-Presbyterian Hospital, New York, New York, USA.
  • Leipsic J; St. Paul's Hospital, University of British Columbia, Vancouver, British Columbia, Canada.
  • Blanke P; St. Paul's Hospital, University of British Columbia, Vancouver, British Columbia, Canada.
  • Jaber W; Cleveland Clinic, Cleveland, Ohio, USA.
  • Mack MJ; Baylor Scott and White Healthcare, Plano, Texas, USA.
  • Clavel MA; Québec Heart and Lung Institute, Université Laval, Quebec City, Quebec, Canada.
  • Salaun E; Québec Heart and Lung Institute, Université Laval, Quebec City, Quebec, Canada.
  • Guzzetti E; Québec Heart and Lung Institute, Université Laval, Quebec City, Quebec, Canada.
  • Annabi MS; Québec Heart and Lung Institute, Université Laval, Quebec City, Quebec, Canada.
  • Bernier M; Québec Heart and Lung Institute, Université Laval, Quebec City, Quebec, Canada.
  • Beaudoin J; Québec Heart and Lung Institute, Université Laval, Quebec City, Quebec, Canada.
  • Khalique OK; Columbia University Medical Center/NewYork-Presbyterian Hospital, New York, New York, USA.
  • Weissman NJ; MedStar Heath Research Institute, Georgetown University, Washington, DC, USA.
  • Douglas P; Duke Clinical Research Institute, Duke University Medical Center, Durham, North Carolina, USA.
  • Bax J; Department of Cardiology, Leiden University Medical Center, Leiden, the Netherlands.
  • Dahou A; Cardiovascular Research Foundation, New York, New York, USA.
  • Xu K; Edwards Lifesciences, Irvine, California, USA.
  • Alu M; Columbia University Medical Center/NewYork-Presbyterian Hospital, New York, New York, USA; Cardiovascular Research Foundation, New York, New York, USA.
  • Rogers E; Edwards Lifesciences, Irvine, California, USA.
  • Leon M; Columbia University Medical Center/NewYork-Presbyterian Hospital, New York, New York, USA; Cardiovascular Research Foundation, New York, New York, USA.
  • Thourani VH; Department of Cardiovascular Surgery, Marcus Valve Center, Piedmont Heart Institute, Atlanta, Georgia, USA.
  • Abbas AE; Oakland University William Beaumont School of Medicine, Auburn Hills, Michigan, USA; Beaumont Hospital Royal Oak, Royal Oak, Michigan, USA.
  • Hahn RT; Columbia University Medical Center/NewYork-Presbyterian Hospital, New York, New York, USA; Cardiovascular Research Foundation, New York, New York, USA.
JACC Cardiovasc Interv ; 14(13): 1466-1477, 2021 07 12.
Article em En | MEDLINE | ID: mdl-34238557
OBJECTIVES: This study aimed to compare incidence and impact of measured prosthesis-patient mismatch (PPMM) versus predicted PPM (PPMP) after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR). BACKGROUND: TAVR studies have used measured effective orifice area indexed (EOAi) to body surface area (BSA) to define PPM, but most SAVR series have used predicted EOAi. This difference may contribute to discrepancies in incidence and outcomes of PPM between series. METHODS: The study analyzed SAVR patients from the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and TAVR patients from the PARTNER 2 SAPIEN 3 Intermediate Risk registry. PPM was classified as moderate if EOAi ≤0.85 cm2/m2 (≤0.70 if obese: body mass index ≥30 kg/m2) and severe if EOAi ≤0.65 cm2/m2 (≤0.55 if obese). PPMM was determined by the core lab-measured EOAi on 30-day echocardiogram. PPMP was determined by 2 methods: 1) using normal EOA reference values previously reported for each valve model and size (PPMP1; n = 929 SAVR, 1,069 TAVR) indexed to BSA; and 2) using normal reference EOA predicted from aortic annulus size measured by computed tomography (PPMP2; n = 864 TAVR only) indexed to BSA. Primary endpoint was the composite of 5-year all-cause death and rehospitalization. RESULTS: The incidence of moderate and severe PPMP was much lower than PPMM in both SAVR (PPMP1: 28.4% and 1.2% vs. PPMM: 31.0% and 23.6%) and TAVR (PPMP1: 21.0% and 0.1% and PPMP2: 17.0% and 0% vs. PPMM: 27.9% and 5.7%). The incidence of severe PPMM and severe PPMP1 was lower in TAVR versus SAVR (P < 0.001). The presence of PPM by any method was associated with higher transprosthetic gradient. Severe PPMP1 was independently associated with events in SAVR after adjustment for sex and Society of Thoracic Surgeons score (hazard ratio: 3.18;95% CI: 1.69-5.96; P < 0.001), whereas no association was observed between PPM by any method and outcomes in TAVR. CONCLUSIONS: EOAi measured by echocardiography results in a higher incidence of PPM following SAVR or TAVR than PPM based on predicted EOAi. Severe PPMP is rare (<1.5%), but is associated with increased all-cause death and rehospitalization after SAVR, whereas it is absent following TAVR.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Próteses Valvulares Cardíacas / Implante de Prótese de Valva Cardíaca / Substituição da Valva Aórtica Transcateter Tipo de estudo: Clinical_trials / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: JACC Cardiovasc Interv Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Próteses Valvulares Cardíacas / Implante de Prótese de Valva Cardíaca / Substituição da Valva Aórtica Transcateter Tipo de estudo: Clinical_trials / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: JACC Cardiovasc Interv Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Canadá