Your browser doesn't support javascript.
loading
A catalog of validity indices for step counting wearable technologies during treadmill walking: the CADENCE-Kids study.
Gould, Zachary R; Mora-Gonzalez, Jose; Aguiar, Elroy J; Schuna, John M; Barreira, Tiago V; Moore, Christopher C; Staudenmayer, John; Tudor-Locke, Catrine.
Afiliação
  • Gould ZR; Department of Kinesiology, University of Massachusetts Amherst, Amherst, MA, USA.
  • Mora-Gonzalez J; College of Health and Human Services, University of North Carolina at Charlotte, 9201 University City Blvd., Charlotte, NC, 28223, USA.
  • Aguiar EJ; Department of Kinesiology, The University of Alabama, Tuscaloosa, AL, USA.
  • Schuna JM; School of Biological and Population Health Sciences, Oregon State University, Corvallis, OR, USA.
  • Barreira TV; Exercise Science Department, Syracuse University, Syracuse, NY, USA.
  • Moore CC; Department of Epidemiology, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA.
  • Staudenmayer J; Department of Mathematics and Statistics, University of Massachusetts Amherst, Amherst, MA, USA.
  • Tudor-Locke C; College of Health and Human Services, University of North Carolina at Charlotte, 9201 University City Blvd., Charlotte, NC, 28223, USA. Tudor-Locke@uncc.edu.
Int J Behav Nutr Phys Act ; 18(1): 97, 2021 07 16.
Article em En | MEDLINE | ID: mdl-34271922
ABSTRACT

BACKGROUND:

Wearable technologies play an important role in measuring physical activity (PA) and promoting health. Standardized validation indices (i.e., accuracy, bias, and precision) compare performance of step counting wearable technologies in young people.

PURPOSE:

To produce a catalog of validity indices for step counting wearable technologies assessed during different treadmill speeds (slow [0.8-3.2 km/h], normal [4.0-6.4 km/h], fast [7.2-8.0 km/h]), wear locations (waist, wrist/arm, thigh, and ankle), and age groups (children, 6-12 years; adolescents, 13-17 years; young adults, 18-20 years).

METHODS:

One hundred seventeen individuals (13.1 ± 4.2 years, 50.4% female) participated in this cross-sectional study and completed 5-min treadmill bouts (0.8 km/h to 8.0 km/h) while wearing eight devices (Waist Actical, ActiGraph GT3X+, NL-1000, SW-200; Wrist ActiGraph GT3X+; Arm SenseWear; Thigh activPAL; Ankle StepWatch). Directly observed steps served as the criterion measure. Accuracy (mean absolute percentage error, MAPE), bias (mean percentage error, MPE), and precision (correlation coefficient, r; standard deviation, SD; coefficient of variation, CoV) were computed.

RESULTS:

Five of the eight tested wearable technologies (i.e., Actical, waist-worn ActiGraph GT3X+, activPAL, StepWatch, and SW-200) performed at < 5% MAPE over the range of normal speeds. More generally, waist (MAPE = 4%), thigh (4%) and ankle (5%) locations displayed higher accuracy than the wrist location (23%) at normal speeds. On average, all wearable technologies displayed the lowest accuracy across slow speeds (MAPE = 50.1 ± 35.5%), and the highest accuracy across normal speeds (MAPE = 15.9 ± 21.7%). Speed and wear location had a significant effect on accuracy and bias (P < 0.001), but not on precision (P > 0.05). Age did not have any effect (P > 0.05).

CONCLUSIONS:

Standardized validation indices focused on accuracy, bias, and precision were cataloged by speed, wear location, and age group to serve as important reference points when selecting and/or evaluating device performance in young people moving forward. Reduced performance can be expected at very slow walking speeds (0.8 to 3.2 km/h) for all devices. Ankle-worn and thigh-worn devices demonstrated the highest accuracy. Speed and wear location had a significant effect on accuracy and bias, but not precision. TRIAL REGISTRATION Clinicaltrials.gov NCT01989104 . Registered November 14, 2013.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Catálogos como Assunto / Caminhada / Actigrafia / Dispositivos Eletrônicos Vestíveis Tipo de estudo: Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Child / Female / Humans / Male Idioma: En Revista: Int J Behav Nutr Phys Act Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Catálogos como Assunto / Caminhada / Actigrafia / Dispositivos Eletrônicos Vestíveis Tipo de estudo: Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Child / Female / Humans / Male Idioma: En Revista: Int J Behav Nutr Phys Act Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos