Your browser doesn't support javascript.
loading
Differentiation of symptomatic and asymptomatic carotid intraplaque hemorrhage using 3D high-resolution diffusion-weighted stack of stars imaging.
Kim, Seong-Eun; Parker, Dennis L; Roberts, John A; Treiman, Gerald S; Alexander, Matthew; Baradaran, Hediyeh; de Havenon, Adam; McNally, J Scott.
Afiliação
  • Kim SE; Utah Center for Advanced Imaging Research, University of Utah, Salt Lake City, Utah, USA.
  • Parker DL; Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA.
  • Roberts JA; Utah Center for Advanced Imaging Research, University of Utah, Salt Lake City, Utah, USA.
  • Treiman GS; Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA.
  • Alexander M; Utah Center for Advanced Imaging Research, University of Utah, Salt Lake City, Utah, USA.
  • Baradaran H; Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA.
  • de Havenon A; Department of Veterans Affairs, VASLCHCS, Salt Lake City, Utah, USA.
  • McNally JS; Utah Center for Advanced Imaging Research, University of Utah, Salt Lake City, Utah, USA.
NMR Biomed ; 34(11): e4582, 2021 11.
Article em En | MEDLINE | ID: mdl-34296793
ABSTRACT
Ischemic events related to carotid disease are far more strongly associated with plaque instability than stenosis. 3D high-resolution diffusion-weighted (DW) imaging can provide quantitative diffusion measurements on carotid atherosclerosis and may improve detection of vulnerable intraplaque hemorrhage (IPH). The 3D DW-stack of stars (SOS) sequence was implemented with 3D SOS acquisition combined with DW preparation. After simulation of signals created from 3D DW-SOS, phantom studies were performed. Three healthy subjects and 20 patients with carotid disease were recruited. Apparent diffusion coefficient (ADC) values were statistically analyzed on three subgroups by using a two-group comparison Wilcoxon-Mann-Whitney U test with p values less than 0.05 symptomatic versus asymptomatic; IPH-positive versus IPH-negative; and IPH-positive symptomatic versus asymptomatic plaques to determine the relationship with plaque vulnerability. ADC values calculated by 3D DW-SOS provided values similar to those calculated from other techniques. Mean ADC of symptomatic plaque was significantly lower than asymptomatic plaque (0.68 ± 0.18 vs. 0.98 ± 0.16 x 10-3  mm2 /s, p < 0.001). ADC was also significantly lower in IPH-positive versus IPH-negative plaque (0.68 ± 0.13 vs. 1.04 ± 0.11 x 10-3  mm2 /s, p < 0.001). Additionally, ADC was significantly lower in symptomatic versus asymptomatic IPH-positive plaque (0.57 ± 0.09 vs. 0.75 ± 0.11 x 10-3  mm2 /s, p < 0.001). Our results provide strong evidence that ADC measurements from 3D DW-SOS correlate with the symptomatic status of extracranial internal carotid artery plaque. Further, ADC improved discrimination of symptomatic plaque in IPH. These data suggest that diffusion characteristics may improve detection of destabilized plaque leading to elevated stroke risk.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose das Carótidas / Imageamento Tridimensional / Imagem de Difusão por Ressonância Magnética / Hemorragia Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: NMR Biomed Assunto da revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose das Carótidas / Imageamento Tridimensional / Imagem de Difusão por Ressonância Magnética / Hemorragia Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: NMR Biomed Assunto da revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos