Your browser doesn't support javascript.
loading
Temporal Alignment of Dual Monitor Accelerometry Recordings.
Brønd, Jan Christian; Pedersen, Natascha Holbæk; Larsen, Kristian Traberg; Grøntved, Anders.
Afiliação
  • Brønd JC; Centre for Research in Childhood Health/Research Unit for Exercise Epidemiology, Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, 5220 Odense, Denmark.
  • Pedersen NH; Centre for Research in Childhood Health/Research Unit for Exercise Epidemiology, Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, 5220 Odense, Denmark.
  • Larsen KT; Centre for Research in Childhood Health/Research Unit for Exercise Epidemiology, Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, 5220 Odense, Denmark.
  • Grøntved A; Centre for Research in Childhood Health/Research Unit for Exercise Epidemiology, Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, 5220 Odense, Denmark.
Sensors (Basel) ; 21(14)2021 Jul 13.
Article em En | MEDLINE | ID: mdl-34300515
ABSTRACT
Combining accelerometry from multiple independent activity monitors worn by the same subject have gained widespread interest with the assessment of physical activity behavior. However, a difference in the real time clock accuracy of the activity monitor introduces a substantial temporal misalignment with long duration recordings which is commonly not considered. In this study, a novel method not requiring human interaction is described for the temporal alignment of triaxial acceleration measured with two independent activity monitors and evaluating the performance with the misalignment manually identified. The method was evaluated with free-living recordings using both combined wrist/hip (n = 9) and thigh/hip device (n = 30) wear locations, and descriptive data on initial offset and accumulated day 7 drift in a large-scale population-based study (n = 2513) were calculated. The results from the Bland-Altman analysis show good agreement between the proposed algorithm and the reference suggesting that the described method is valid for reducing the temporal misalignment and thus reduce the measurement error with aggregated data. Applying the algorithm to the n = 2513 samples worn for 7-days suggest a wide and substantial issue with drift over time when each subject wears two independent activity monitors.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acelerometria / Monitores de Aptidão Física Limite: Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Dinamarca

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acelerometria / Monitores de Aptidão Física Limite: Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Dinamarca