Your browser doesn't support javascript.
loading
Influence of Single Stent Size and Tandem Stents Subject to Extrinsic Ureteral Obstruction and Stent Occlusion on Stent Failure.
Amitay-Rosen, Tal; Shilo, Yaniv; Dror, Ishai; Berkowitz, Brian.
Afiliação
  • Amitay-Rosen T; Department of Physical Chemistry, Institute for Biological Research, Ness-Ziona, Israel.
  • Shilo Y; Department of Earth and Planetary Sciences, Weizmann Institute of Science, Rehovot, Israel.
  • Dror I; Department of Urology, Kaplan Medical Center, Rehovot, Israel.
  • Berkowitz B; Department of Earth and Planetary Sciences, Weizmann Institute of Science, Rehovot, Israel.
J Endourol ; 36(2): 236-242, 2022 02.
Article em En | MEDLINE | ID: mdl-34314233
Background and Purpose: Drainage of obstructed kidney attributable to extrinsic ureteral obstruction (EUO), required to prevent renal damage, is often achieved using Double-J ureteral stents. However, these stents fail frequently, and there is considerable debate regarding what stent size, type, and configuration offer the best option for sustained drainage. In this study, we examine the impact of stent diameter and choice of single/tandem configuration, subject to EUO and various degrees of stent occlusion, on stent failure. Materials and Methods: Computational fluid dynamics simulations and an in vitro ureter-stent experiment enabled quantification of flow behavior in stented ureters subject to EUO and stent occlusions. Various single and tandem stents under EUO were considered. In each simulation and experiment, changes in renal pressure were monitored for different degrees of stent lumen occlusion, and onset of stent failure as well as simulated distributions of fluid flow between stent and ureter lumina were determined. Results: For an encircling EUO that completely obstructs the ureter lumen, with or without partial stent occlusion, the choice of stent size/configuration has little effect on renal pressure. The pressure increases significantly for ∼90% stent lumen occlusion, with failure at >95% occlusion, independent of stent diameter or a tandem configuration, and with little influence of occlusion length along the stent. Conclusions: Stent failure rate is independent of stent diameter or single/tandem configuration, for the same percentage of stent lumen occlusion, in this model. Stent failure incidence may decrease for larger diameter stents and tandem configurations, because of the larger luminal area.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ureter / Obstrução Ureteral Limite: Humans Idioma: En Revista: J Endourol Assunto da revista: UROLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Israel

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ureter / Obstrução Ureteral Limite: Humans Idioma: En Revista: J Endourol Assunto da revista: UROLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Israel