Your browser doesn't support javascript.
loading
Shear-bond strength and optical properties of short fiber-reinforced CAD/CAM composite blocks.
Mangoush, Enas; Lassila, Lippo; Vallittu, Pekka K; Garoushi, Sufyan.
Afiliação
  • Mangoush E; Department of Biomaterials Science and Turku Clinical Biomaterial Center -TCBC, Institute of Dentistry, University of Turku, Turku, Finland.
  • Lassila L; Department of Biomaterials Science and Turku Clinical Biomaterial Center -TCBC, Institute of Dentistry, University of Turku, Turku, Finland.
  • Vallittu PK; Department of Biomaterials Science and Turku Clinical Biomaterial Center -TCBC, Institute of Dentistry, University of Turku, Turku, Finland.
  • Garoushi S; City of Turku Welfare Division, Oral Health Care, Turku, Finland.
Eur J Oral Sci ; 129(5): e12815, 2021 10.
Article em En | MEDLINE | ID: mdl-34322917
ABSTRACT
The aim of this study was to assess the shear-bond strength (SBS) of resin-luting cement to experimental short fiber-reinforced CAD/CAM composite (SFRC) compared to conventional CAD/CAM (Cerasmart 270), 3D printed (GC TEMP PRINT, Pro3dure GR-17), and laboratory (Gradia Plus) composites. Moreover, translucency parameter values and light transmission were evaluated. For each of the five types of composites, discs were prepared (n = 16/group) and divided into subgroups (n = 8/group) according to surface treatment protocol (hydrofluoric acid or air-particle abrasion). SBS test was performed using universal testing machine until failure, and failure modes were visually analyzed. Translucency parameter and curing-light transmission values through 1, 2, and 3 mm thickness were quantified using spectrophotometry and the MARC resin calibrator, respectively. Scanning electron microscopy (SEM) was used to examine the CAD/CAM composites after surface treatment. Composite type and surface treatment had a significant effect on SBS. Laboratory composite showed the highest SBS value (22.4 MPa). Cerasmart 270 exhibited higher translucency parameter values (19.8, 11.0, 5.0) than SFRC (14.5, 5.2, 1.6) at the three composite thicknesses tested. Air-particle abrasion was more effective in enhancing SBS than acid etching. Experimental SFRC CAD/CAM composite showed higher SBS values than Cerasmart 270. For all composites, translucency parameter values and light transmission decreased as thickness increased.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Eur J Oral Sci Assunto da revista: ODONTOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Finlândia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Eur J Oral Sci Assunto da revista: ODONTOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Finlândia