Your browser doesn't support javascript.
loading
The Contribution of a Collagen Patch Coated With Fibrin Glue in Sealing Upper Gastrointestinal Defects: An Experimental Study.
Christodoulidis, Gregory; Samara, Athina A; Floros, Theodoros; Karakantas, Kostas-Sotirios; Zotos, Prokopis-Andreas; Koutras, Antonios; Tepetes, Konstantinos.
Afiliação
  • Christodoulidis G; Laboratory of Experimental Surgery, University of Thessaly, Larissa, Greece.
  • Samara AA; Laboratory of Experimental Surgery, University of Thessaly, Larissa, Greece; at.samara93@gmail.com.
  • Floros T; Laboratory of Experimental Surgery, University of Thessaly, Larissa, Greece.
  • Karakantas KS; Laboratory of Experimental Surgery, University of Thessaly, Larissa, Greece.
  • Zotos PA; Laboratory of Experimental Surgery, University of Thessaly, Larissa, Greece.
  • Koutras A; 1 Department of Obstetrics and Gynecology, Alexandra Maternity Hospital, National and Kapodistrian University of Athens, Athens, Greece.
  • Tepetes K; Laboratory of Experimental Surgery, University of Thessaly, Larissa, Greece.
In Vivo ; 35(5): 2697-2702, 2021.
Article em En | MEDLINE | ID: mdl-34410958
ABSTRACT
BACKGROUND/

AIM:

We aimed to evaluate the safety and efficacy of sealing primary upper gastrointestinal (GI) perforations with a collagen patch coated with fibrin glue (Tachosil®). MATERIALS AND

METHODS:

Thirty New Zealand rabbits were used in this study. An iatrogenic gastric perforation was created, and primary repair was performed on the control group. Tachosil®, without suturing the deficit, was used in the intervention group.

RESULTS:

Leakage was observed in 3 (20%) and 2 rabbits (13.3%) in the control and intervention group, respectively; however, the difference was not statistically significant (p=0.62). Moreover, adhesions formed in 10/15 and all rabbits in the intervention and control group, respectively (p=0.014); however, based on the Zuhlke adhesion's classification, there was no statistically significant difference between the two groups.

CONCLUSION:

A collagen patch coated with fibrin glue is not a replacement but can be considered a safe option for the reinforcement of suturing, preventing leakages in the upper GI tract.