Your browser doesn't support javascript.
loading
Non-enzymatic electrochemical cholesterol sensor based on strong host-guest interactions with a polymer of intrinsic microporosity (PIM) with DFT study.
Jahani, Negin; Amiri, Mandana; Ghiasi, Mina; Imanzadeh, Hamideh; Boukherroub, Rabah; Szunerits, Sabine; Marken, Frank; McKeown, Neil B.
Afiliação
  • Jahani N; Department of Chemistry, University of Mohaghegh Ardabili, Ardabil, 59166-11367, Iran.
  • Amiri M; Department of Chemistry, University of Mohaghegh Ardabili, Ardabil, 59166-11367, Iran. mandanaamiri@uma.ac.ir.
  • Ghiasi M; Department of Chemistry, Faculty of Physics and Chemistry, Alzahra University, Tehran, 1993893973, Iran.
  • Imanzadeh H; Department of Chemistry, University of Mohaghegh Ardabili, Ardabil, 59166-11367, Iran.
  • Boukherroub R; Univ. Lille, CNRS, Centrale Lille Univ. Polytechnique Hauts-de-France, UMR 8520 - IEMN, 59000, Lille, France.
  • Szunerits S; Univ. Lille, CNRS, Centrale Lille Univ. Polytechnique Hauts-de-France, UMR 8520 - IEMN, 59000, Lille, France.
  • Marken F; Department of Chemistry, University of Bath, Bath, BA2 7AY, UK.
  • McKeown NB; School of Chemistry, University of Edinburgh, David Brewster Road, Edinburgh, EH9 3FJ, UK.
Anal Bioanal Chem ; 413(26): 6523-6533, 2021 Nov.
Article em En | MEDLINE | ID: mdl-34462789
ABSTRACT
Advances in materials science have accelerated the development of diagnostic tools with the last decade witnessing the development of enzyme-free sensors, owing to the improved stability, low cost and simple fabrication of component materials. However, the specificity of non-enzymatic sensors for certain analytes still represents a challenging task, for example the determination of cholesterol level in blood is vital due to its medical relevance. In this work, a reagent displacement assay for cholesterol sensing in serum samples was developed. It is based on coating of a glassy carbon electrode with a polymer of intrinsic microporosity (PIM) that forms a host-guest complex with methylene blue (MB). In the presence of cholesterol, the MB electroactive probe was displaced due to the stronger association of cholesterol guest to the PIM host. The decrease in the oxidative current was proportional to the cholesterol concentration achieving a detection limit of approximately 0.1 nM. Moreover, to further assist the experimental studies, comprehensive theoretical calculations are also performed by using density functional theory (DFT) calculations.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Colesterol / Técnicas Eletroquímicas Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Irã

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Colesterol / Técnicas Eletroquímicas Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Irã