Your browser doesn't support javascript.
loading
Micra-AV leadless pacemaker and atrioventricular (dys)synchrony: A stepwise process.
Mitacchione, Gianfranco; Schiavone, Marco; Gasperetti, Alessio; Ruggiero, Diego; Denora, Marialessia; Viecca, Maurizio; Forleo, Giovanni Battista.
Afiliação
  • Mitacchione G; Cardiology Unit, ASST-Fatebenefratelli Sacco, Luigi Sacco University Hospital, Milan, Italy.
  • Schiavone M; Cardiology Unit, ASST-Fatebenefratelli Sacco, Luigi Sacco University Hospital, Milan, Italy.
  • Gasperetti A; Cardiology Unit, ASST-Fatebenefratelli Sacco, Luigi Sacco University Hospital, Milan, Italy.
  • Ruggiero D; Cardiology Unit, ASST-Fatebenefratelli Sacco, Luigi Sacco University Hospital, Milan, Italy.
  • Denora M; Cardiology Unit, ASST-Fatebenefratelli Sacco, Luigi Sacco University Hospital, Milan, Italy.
  • Viecca M; Cardiology Unit, ASST-Fatebenefratelli Sacco, Luigi Sacco University Hospital, Milan, Italy.
  • Forleo GB; Cardiology Unit, ASST-Fatebenefratelli Sacco, Luigi Sacco University Hospital, Milan, Italy.
Pacing Clin Electrophysiol ; 44(10): 1738-1742, 2021 Oct.
Article em En | MEDLINE | ID: mdl-34463365
ABSTRACT
Leadless pacemakers have become a major breakthrough in the management of bradyarrhythmia as an attractive alternative to the standard transvenous pacemakers, but safety and long-term outcomes of the new Micra-AV, which is capable guarantee atrioventricular (AV) synchrony, have been poorly described. Hence, we describe how we managed a 57-year-old patient who developed pacemaker syndrome due to significant Micra-AV dyssynchrony. This case emphasizes how leadless pacemaker AV synchrony could be overestimated, thereby requiring a stepwise process leading to adequate device reprogramming. Holter-ECG monitoring and exercise test resulted to be valuable tools for an early detection of inadequate AV synchrony, integrating and completing device reports.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Algoritmos / Falha de Prótese / Bloqueio Atrioventricular Tipo de estudo: Screening_studies Limite: Female / Humans / Middle aged Idioma: En Revista: Pacing Clin Electrophysiol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Algoritmos / Falha de Prótese / Bloqueio Atrioventricular Tipo de estudo: Screening_studies Limite: Female / Humans / Middle aged Idioma: En Revista: Pacing Clin Electrophysiol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Itália