Sympathetic vasoconstrictor activity before and after left ventricular assist device implantation in patients with end-stage heart failure.
Heusser, Karsten; Wittkoepper, Judith; Bara, Christoph; Haverich, Axel; Diedrich, André; Levine, Benjamin D; Schmitto, Jan D; Jordan, Jens; Tank, Jens.
Afiliação
  • Heusser K; Institute of Aerospace Medicine, German Aerospace Center, Cologne, Germany.
  • Wittkoepper J; Institute of Clinical Pharmacology, Hannover Medical School, Hannover, Germany.
  • Bara C; Department of Cardiac, Thoracic, Transplantation, and Vascular Surgery, Hannover Medical School, Hannover, Germany.
  • Haverich A; Department of Cardiac, Thoracic, Transplantation, and Vascular Surgery, Hannover Medical School, Hannover, Germany.
  • Diedrich A; Department of Medicine, Division of Clinical Pharmacology, Autonomic Dysfunction Center, Vanderbilt University Medical Center & Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA.
  • Levine BD; Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Hospital, Dallas, TX, USA.
  • Schmitto JD; Department of Internal Medicine, Division of Cardiology, University of Texas Southwestern Medical Center, Dallas, TX, USA.
  • Jordan J; Department of Cardiac, Thoracic, Transplantation, and Vascular Surgery, Hannover Medical School, Hannover, Germany.
  • Tank J; Institute of Aerospace Medicine, German Aerospace Center, Cologne, Germany.
Eur J Heart Fail ; 23(11): 1955-1959, 2021 11.
Article em En | MEDLINE | ID: mdl-34496114
ABSTRACT

AIMS:

Sympathetic overactivity, which predicts poor outcome in patients with heart failure, normalizes following cardiac transplantation. We tested the hypothesis that haemodynamic improvement following left ventricular assist device (LVAD) implantation is also associated with reductions in centrally generated sympathetic activity. METHODS AND

RESULTS:

In eight patients with heart failure (two women, six men, age 44-66 years), we continuously recorded electrocardiogram, beat-to-beat finger blood pressure, respiration, and muscle sympathetic nerve activity (MSNA) before and after implantation of the continuous-flow LVAD devices HeartWare HVAD (n = 4) and HeartMate II (n = 2), and the non-continuous-flow device HeartMate 3 (n = 2). LVAD implantation increased cardiac output by 1.29 ± 0.88 L/min (P = 0.060) and mean arterial pressure by 16.2 ± 7.9 mmHg (P < 0.001), while reducing pulse pressure by 25.3 ± 9.8 mmHg (P < 0.001). LVAD implantation did not change MSNA burst frequency (-1.3 ± 7.5 bursts/min, P = 0.636), total activity (+0.62 ± 1.83 au, P = 0.369), or normalized activity (+0.63 ± 4.23, P = 0.685). MSNA burst incidence was decreased (-7.8 ± 9.3 bursts/100 heart beats, P = 0.049). However, cardiac ectopy altered MSNA bursting patterns that could be mistaken for sympatholysis.

CONCLUSION:

Implantation of current design LVAD does not consistently normalize sympathetic activity in patients with end-stage heart failure despite haemodynamic improvement.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coração Auxiliar / Insuficiência Cardíaca Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Heart Fail Assunto da revista: CARDIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coração Auxiliar / Insuficiência Cardíaca Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Heart Fail Assunto da revista: CARDIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Alemanha