Detection of obstructive sleep apnea using Belun Sleep Platform wearable with neural network-based algorithm and its combined use with STOP-Bang questionnaire.
PLoS One
; 16(10): e0258040, 2021.
Article
em En
| MEDLINE
| ID: mdl-34634070
ABSTRACT
Many wearables allow physiological data acquisition in sleep and enable clinicians to assess sleep outside of sleep labs. Belun Sleep Platform (BSP) is a novel neural network-based home sleep apnea testing system utilizing a wearable ring device to detect obstructive sleep apnea (OSA). The objective of the study is to assess the performance of BSP for the evaluation of OSA. Subjects who take heart rate-affecting medications and those with non-arrhythmic comorbidities were included in this cohort. Polysomnography (PSG) studies were performed simultaneously with the Belun Ring in individuals who were referred to the sleep lab for an overnight sleep study. The sleep studies were manually scored using the American Academy of Sleep Medicine Scoring Manual (version 2.4) with 4% desaturation hypopnea criteria. A total of 78 subjects were recruited. Of these, 45% had AHI < 5; 18% had AHI 5-15; 19% had AHI 15-30; 18% had AHI ≥ 30. The Belun apnea-hypopnea index (bAHI) correlated well with the PSG-AHI (r = 0.888, P < 0.001). The Belun total sleep time (bTST) and PSG-TST had a high correlation coefficient (r = 0.967, P < 0.001). The accuracy, sensitivity, specificity in categorizing AHI ≥ 15 were 0.808 [95% CI, 0.703-0.888], 0.931 [95% CI, 0.772-0.992], and 0.735 [95% CI, 0.589-0.850], respectively. The use of beta-blocker/calcium-receptor antagonist and the presence of comorbidities did not negatively affect the sensitivity and specificity of BSP in predicting OSA. A diagnostic algorithm combining STOP-Bang cutoff of 5 and bAHI cutoff of 15 events/h demonstrated an accuracy, sensitivity, specificity of 0.938 [95% CI, 0.828-0.987], 0.944 [95% CI, 0.727-0.999], and 0.933 [95% CI, 0.779-0.992], respectively, for the diagnosis of moderate to severe OSA. BSP is a promising testing tool for OSA assessment and can potentially be incorporated into clinical practices for the identification of OSA. Trial registration ClinicalTrial.org NCT03997916 https//clinicaltrials.gov/ct2/show/NCT03997916?term=belun+ring&draw=2&rank=1.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Apneia Obstrutiva do Sono
/
Dispositivos Eletrônicos Vestíveis
Tipo de estudo:
Clinical_trials
/
Diagnostic_studies
/
Etiology_studies
/
Guideline
/
Incidence_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Adult
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
PLoS One
Assunto da revista:
CIENCIA
/
MEDICINA
Ano de publicação:
2021
Tipo de documento:
Article
País de afiliação:
Estados Unidos