Your browser doesn't support javascript.
loading
SOFTWARE-ASSISTED IMAGE ANALYSIS FOR IDENTIFICATION AND QUANTIFICATION OF HEPATIC SINUSOIDAL DILATATION AND CENTRILOBULAR FIBROSIS.
Gewehr, Douglas Mesadri; Giovanini, Allan Fernando; Munhoz, Sofia Inez; Nagashima, Seigo; Bertoldi, Andressa de Souza; Sobral, Ana Cristina Lira; Kubrusly, Fernando Bermudez; Kubrusly, Luiz Fernando.
Afiliação
  • Gewehr DM; Mackenzie Evangelical Faculty of Paraná, Curitiba, Paraná, Brazil.
  • Giovanini AF; Denton Cooley Institute of Research, Science and Technology, Curitiba, Paraná, Brazil.
  • Munhoz SI; Curitiba Heart Institute, Curitiba, Paraná, Brazil.
  • Nagashima S; Mackenzie Evangelical Faculty of Paraná, Curitiba, Paraná, Brazil.
  • Bertoldi AS; Mackenzie Evangelical Faculty of Paraná, Curitiba, Paraná, Brazil.
  • Sobral ACL; Denton Cooley Institute of Research, Science and Technology, Curitiba, Paraná, Brazil.
  • Kubrusly FB; Laboratory of Experimental Pathology of Health and Biological Sciences, Pontifícia Universidade Católica do Paraná, Curitiba, Paraná, Brazil.
  • Kubrusly LF; Denton Cooley Institute of Research, Science and Technology, Curitiba, Paraná, Brazil.
Arq Bras Cir Dig ; 34(2): e1608, 2021.
Article em En, Pt | MEDLINE | ID: mdl-34669894
BACKGROUND: Heart dysfunction and liver disease often coexist because of systemic disorders. Any cause of right ventricular failure may precipitate hepatic congestion and fibrosis. Digital image technologies have been introduced to pathology diagnosis, allowing an objective quantitative assessment. The quantification of fibrous tissue in liver biopsy sections is extremely important in the classification, diagnosis and grading of chronic liver disease. AIM: To create a semi-automatic computerized protocol to quantify any amount of centrilobular fibrosis and sinusoidal dilatation in liver Masson's Trichrome-stained specimen. METHOD: Once fibrosis had been established, liver samples were collected, histologically processed, stained with Masson's trichrome, and whole-slide images were captured with an appropriated digital pathology slide scanner. After, a random selection of the regions of interest (ROI's) was conducted. The data were subjected to software-assisted image analysis (ImageJ®). RESULTS: The analysis of 250 ROI's allowed to empirically obtain the best application settings to identify the centrilobular fibrosis (CF) and sinusoidal lumen (SL). After the establishment of the colour threshold application settings, an in-house Macro was recorded to set the measurements (fraction area and total area) and calculate the CF and SL ratios by an automatic batch processing. CONCLUSION: Was possible to create a more detailed method that identifies and quantifies the area occupied by fibrous tissue and sinusoidal lumen in Masson's trichrome-stained livers specimens.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Software Tipo de estudo: Diagnostic_studies / Guideline Limite: Humans Idioma: En / Pt Revista: Arq Bras Cir Dig Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Software Tipo de estudo: Diagnostic_studies / Guideline Limite: Humans Idioma: En / Pt Revista: Arq Bras Cir Dig Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Brasil