Your browser doesn't support javascript.
loading
A spectroscopic hike in the U-O phase diagram.
Prieur, Damien; Desagulier, Marie Margaux; Neuville, Daniel R; Guéneau, Christine; Epifano, Enrica; Dardenne, Kathy; Rothe, Joerg; Martin, Philippe.
Afiliação
  • Prieur D; Helmholtz Zentrum Dresden-Rossendorf, Institute of Resource Ecology, PO Box 510119, 013014 Dresden, Germany.
  • Desagulier MM; CEA, DES, ISEC, DMRC, University of Montpellier, Marcoule, France.
  • Neuville DR; Université de Paris, Institut de Physique du Globe de Paris, CNRS, 75238 Paris Cedex 05, France.
  • Guéneau C; Université Paris-Saclay, CEA, Service de la Corrosion et du Comportement des Matériaux dans leur Environnement (SCCME), 91191 Gif-sur-Yvette, France.
  • Epifano E; CIRIMAT Laboratory, University of Toulouse, CNRS, INPT, UPS, ENSIACET, 4 Allée Emile Monso, BP-44362, 31030 Toulouse Cedex 4, France.
  • Dardenne K; Karlsruhe Institute of Technology (KIT), Institute for Nuclear Waste Disposal (INE), PO Box 3640, D-76021 Karlsruhe, Germany.
  • Rothe J; Karlsruhe Institute of Technology (KIT), Institute for Nuclear Waste Disposal (INE), PO Box 3640, D-76021 Karlsruhe, Germany.
  • Martin P; CEA, DES, ISEC, DMRC, University of Montpellier, Marcoule, France.
J Synchrotron Radiat ; 28(Pt 6): 1684-1691, 2021 Nov 01.
Article em En | MEDLINE | ID: mdl-34738922
The U-O phase diagram is of paramount interest for nuclear-related applications and has therefore been extensively studied. Experimental data have been gathered to feed the thermodynamic calculations and achieve an optimization of the U-O system modelling. Although considered as well established, a critical assessment of this large body of experimental data is necessary, especially in light of the recent development of new techniques applicable to actinide materials. Here we show how in situ X-ray absorption near-edge structure (XANES) is suitable and relevant for phase diagram determination. New experimental data points have been collected using this method and discussed in regard to the available data. Comparing our experimental data with thermodynamic calculations, we observe that the current version of the U-O phase diagram misses some experimental data in specific domains. This lack of experimental data generates inaccuracy in the model, which can be overcome using in situ XANES. Indeed, as shown in the paper, this method is suitable for collecting experimental data in non-ambient conditions and for multiphasic systems.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Synchrotron Radiat Assunto da revista: RADIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Synchrotron Radiat Assunto da revista: RADIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Alemanha