Your browser doesn't support javascript.
loading
A Rat Lung Transplantation Model of Warm Ischemia/Reperfusion Injury: Optimizations to Improve Outcomes.
Lee, Yong Gyu; Kim, Jung-Lye; Palmer, Andre F; Reader, Brenda F; Ma, Jianjie; Black, Sylvester M; Whitson, Bryan A.
Afiliação
  • Lee YG; Department of Surgery Division of Cardiac Surgery, The Ohio State University Wexner Medical Center; The Collaboration for Organ Perfusion, Protection, Engineering and Regeneration (COPPER) Laboratory, The Ohio State University College of Medicine.
  • Kim JL; Department of Surgery Division of Cardiac Surgery, The Ohio State University Wexner Medical Center; The Collaboration for Organ Perfusion, Protection, Engineering and Regeneration (COPPER) Laboratory, The Ohio State University College of Medicine.
  • Palmer AF; William G. Lowrie Department of Chemical and Biomolecular Engineering, College of Engineering, The Ohio State University.
  • Reader BF; Comprehensive Transplant Center, The Ohio State University Wexner Medical Center.
  • Ma J; Department of Surgery Division of Cardiac Surgery, The Ohio State University Wexner Medical Center.
  • Black SM; The Collaboration for Organ Perfusion, Protection, Engineering and Regeneration (COPPER) Laboratory, The Ohio State University College of Medicine; Comprehensive Transplant Center, The Ohio State University Wexner Medical Center.
  • Whitson BA; Department of Surgery Division of Cardiac Surgery, The Ohio State University Wexner Medical Center; The Collaboration for Organ Perfusion, Protection, Engineering and Regeneration (COPPER) Laboratory, The Ohio State University College of Medicine; Bryan.Whitson@osumc.edu.
J Vis Exp ; (176)2021 10 28.
Article em En | MEDLINE | ID: mdl-34779431
ABSTRACT
From our experience with rat lung transplantation, we have found several areas for improvement. Information in the existing literature regarding methods for choosing appropriate cuff sizes for the pulmonary vein (PV), pulmonary artery (PA), or bronchus (Br) are varied, thus making the determination of proper cuff size during rat lung transplantation an exercise of trial and error. By standardizing the cuffing technique to use the smallest effective cuff appropriate for the size of the vessel or bronchus, one can make the transplantation procedure safer, faster, and more successful. Since diameters of the PV, PA, and Br are related to the body weight of the rat, we present a strategy to choosing an appropriate size using a weight-based guide. Since lung volume is also related to body weight, we recommend that this relationship should also be considered when choosing the proper volume of air for donor lung inflation during warm ischemia as well as for the proper volume of PBS to be instilled during bronchoalveolar lavage (BAL) fluid collection. We also describe methods for 4th intercostal space dissection, wound closure, and sample collection from both the native and transplanted lobes.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Traumatismo por Reperfusão / Transplante de Pulmão Limite: Animals Idioma: En Revista: J Vis Exp Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Traumatismo por Reperfusão / Transplante de Pulmão Limite: Animals Idioma: En Revista: J Vis Exp Ano de publicação: 2021 Tipo de documento: Article