Your browser doesn't support javascript.
loading
Biomechanical In Vitro and Finite Element Study on Different Sagittal Alignment Postures of the Lumbar Spine During Multiaxial Daily Motion.
Wilmanns, Nadja; Beckmann, Agnes; Nicolini, Luis Fernando; Herren, Christian; Sobottke, Rolf; Hildebrand, Frank; Siewe, Jan; Kobbe, Philipp; Markert, Bernd; Stoffel, Marcus.
Afiliação
  • Wilmanns N; Institute of General Mechanics, RWTH Aachen University, Eilfschornsteinstraße 18, Aachen 52062, Germany.
  • Beckmann A; Institute of General Mechanics, RWTH Aachen University, Eilfschornsteinstraße 18, Aachen 52062, Germany.
  • Nicolini LF; Institute of General Mechanics, RWTH Aachen University, Eilfschornsteinstraße 18, Aachen 52062, Germany.
  • Herren C; Department for Trauma and Reconstructive Surgery, University Hospital RWTH, Aachen Pauwelsstraße 30, Aachen 52074, Germany.
  • Sobottke R; Rhein-Maas Klinik Department of Orthopaedics and Trauma Surgery, Mauerfeldchen 25, Würselen 52146, Germany.
  • Hildebrand F; Department for Trauma and Reconstructive Surgery, University Hospital RWTH Aachen, Pauwelsstraße 30, Aachen 52074, Germany.
  • Siewe J; Department of Spine Surgery, Klinikum Leverkusen gGmbH, Am Gesundheitspark 11, Leverkusen 51375, Germany; Faculty of Medicine, University Hospital of Cologne, Joseph-Stelzmann-Str. 20, Köln 50931, Germany.
  • Kobbe P; Department for Trauma and Reconstructive Surgery, University Hospital RWTH Aachen, Pauwelsstraße 30, Aachen 52074, Germany.
  • Markert B; Institute of General Mechanics, RWTH Aachen University, Eilfschornsteinstraße 18, Aachen 52062, Germany.
  • Stoffel M; Institute of General Mechanics, RWTH Aachen University, Eilfschornsteinstraße 18, Aachen 52062, Germany.
J Biomech Eng ; 144(7)2022 07 01.
Article em En | MEDLINE | ID: mdl-34802059
ABSTRACT
Lumbar lordotic correction (LLC), the gold standard treatment for sagittal spinal malalignment (SMA), and its effect on sagittal balance have been critically discussed in recent studies. This paper assesses the biomechanical response of the spinal components to LLC as an additional factor for the evaluation of LLC. Human lumbar spines (L2L5) were loaded with combined bending moments in flexion (Flex)/extension (Ex) or lateral bending (LatBend) and axial rotation (AxRot) in a physiological environment. We examined the dependency of AxRot range of motion (RoM) on the applied bending moment. The results were used to validate a finite element (FE) model of the lumbar spine. With this model, the biomechanical response of the intervertebral discs (IVD) and facet joints under daily motion was studied for different sagittal alignment postures, simulated by a motion in Flex/Ex direction. Applied bending moments decreased AxRot RoM significantly (all P < 0.001). A stronger decline of AxRot RoM for Ex than for Flex direction was observed (all P < 0.0001). Our simulated results largely agreed with the experimental data (all R2 > 0.79). During the daily motion, the IVD was loaded higher with increasing lumbar lordosis (LL) for all evaluated values at L2L3 and L3L4 and posterior annulus stress (AS) at L4L5 (all P < 0.0476). The results of this study indicate that LLC with large extensions of LL may not always be advantageous regarding the biomechanical loading of the IVD. This finding may be used to improve the planning process of LLC treatments.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Articulação Zigapofisária / Vértebras Lombares Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Biomech Eng Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Articulação Zigapofisária / Vértebras Lombares Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Biomech Eng Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha