Your browser doesn't support javascript.
loading
Proposal criteria of paradoxical low-flow low-gradient aortic stenosis for predicting prognosis in patients undergoing transcatheter aortic valve implantation.
Tanino, Tomomi; Yufu, Kunio; Shuto, Takashi; Sato, Hiroki; Takano, Masayuki; Ishii, Yumi; Kira, Shintaro; Saito, Shotaro; Kondo, Hidekazu; Fukui, Akira; Fukuda, Tomoko; Akioka, Hidefumi; Teshima, Yasushi; Wada, Tomoyuki; Miyamoto, Shinji; Takahashi, Naohiko.
Afiliação
  • Tanino T; Department of Cardiology and Clinical Examination, Faculty of Medicine, Oita University, Yufu, Oita, 879-5593, Japan.
  • Yufu K; Department of Cardiology and Clinical Examination, Faculty of Medicine, Oita University, Yufu, Oita, 879-5593, Japan. yufukuni@oita-u.ac.jp.
  • Shuto T; Department of Cardiovascular Surgery, Faculty of Medicine, Oita University, Yufu, Japan.
  • Sato H; Department of Cardiology and Clinical Examination, Faculty of Medicine, Oita University, Yufu, Oita, 879-5593, Japan.
  • Takano M; Department of Cardiology and Clinical Examination, Faculty of Medicine, Oita University, Yufu, Oita, 879-5593, Japan.
  • Ishii Y; Department of Cardiology and Clinical Examination, Faculty of Medicine, Oita University, Yufu, Oita, 879-5593, Japan.
  • Kira S; Department of Cardiology and Clinical Examination, Faculty of Medicine, Oita University, Yufu, Oita, 879-5593, Japan.
  • Saito S; Department of Cardiology and Clinical Examination, Faculty of Medicine, Oita University, Yufu, Oita, 879-5593, Japan.
  • Kondo H; Department of Cardiology and Clinical Examination, Faculty of Medicine, Oita University, Yufu, Oita, 879-5593, Japan.
  • Fukui A; Department of Cardiology and Clinical Examination, Faculty of Medicine, Oita University, Yufu, Oita, 879-5593, Japan.
  • Fukuda T; Department of Cardiology and Clinical Examination, Faculty of Medicine, Oita University, Yufu, Oita, 879-5593, Japan.
  • Akioka H; Department of Cardiology and Clinical Examination, Faculty of Medicine, Oita University, Yufu, Oita, 879-5593, Japan.
  • Teshima Y; Department of Cardiology and Clinical Examination, Faculty of Medicine, Oita University, Yufu, Oita, 879-5593, Japan.
  • Wada T; Department of Cardiovascular Surgery, Faculty of Medicine, Oita University, Yufu, Japan.
  • Miyamoto S; Department of Cardiovascular Surgery, Faculty of Medicine, Oita University, Yufu, Japan.
  • Takahashi N; Department of Cardiology and Clinical Examination, Faculty of Medicine, Oita University, Yufu, Oita, 879-5593, Japan.
Heart Vessels ; 37(6): 1044-1054, 2022 Jun.
Article em En | MEDLINE | ID: mdl-34822000

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Substituição da Valva Aórtica Transcateter Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Heart Vessels Assunto da revista: CARDIOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Substituição da Valva Aórtica Transcateter Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Heart Vessels Assunto da revista: CARDIOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Japão