Your browser doesn't support javascript.
loading
Performance of a Histidine Rich Protein-2 Based (First Response) and a p-Lactate Dehydrogenase-based (Optimal) Rapid Diagnostic Test for Diagnosis of Malaria in Patients With Pediatric Sickle Cell Disease.
Adjei, George O; Sulley, Abdul M; Goka, Bamenla Q; Enweronu-Laryea, Christabel; Renner, Lorna; Alifrangis, Michael; Kurtzhals, Jorgen A L.
Afiliação
  • Adjei GO; Centre for Tropical Clinical Pharmacology and Therapeutics, University of Ghana Medical School, University of Ghana, Accra, Ghana.
  • Sulley AM; Centre for Tropical Clinical Pharmacology and Therapeutics, University of Ghana Medical School, University of Ghana, Accra, Ghana.
  • Goka BQ; Department of Child Health, University of Ghana Medical School, University of Ghana, Accra, Ghana.
  • Enweronu-Laryea C; Department of Child Health, University of Ghana Medical School, University of Ghana, Accra, Ghana.
  • Renner L; Department of Child Health, University of Ghana Medical School, University of Ghana, Accra, Ghana.
  • Alifrangis M; Centre for Medical Parasitology at Department of Immunology and Microbiology, University of Copenhagen, Copenhagen, Denmark.
  • Kurtzhals JAL; Department of Clinical Microbiology and Department of Infectious Diseases, Copenhagen University Hospital (Rigshospitalet), Copenhagen, Denmark.
Clin Infect Dis ; 75(3): 435-441, 2022 08 31.
Article em En | MEDLINE | ID: mdl-34849647
ABSTRACT

BACKGROUND:

Rapid diagnostic tests (RDTs) have been extensively evaluated and play an important role in malaria diagnosis. However, the accuracy of RDTs for malaria diagnosis in patients with sickle cell disease (SCD) is unknown.

METHODS:

We compared the performance of a histidine rich protein 2 (HRP-2)-based RDT (First Response) and a lactate dehydrogenase (LDH)-based RDT (Optimal) with routine microscopy as reference standard in 445 children with SCD and an acute febrile illness in Accra, Ghana.

RESULTS:

The overall sensitivity, specificity, and positive and negative predictive values of the HRP-2-based RDTs were 100%, 95.7%, 73.8%, and 100%, respectively. Comparable values for the LDH-based RDTs were 91.7%, 99.5%, 95.7%, and 99.0%, respectively. A total of 423 results were true in both tests, 1 result was false in both tests, 16 results were false in the HRP-2 test only, and 5 were false in the LDH test only (McNemar test, P = .03). At follow-up, 73.7% (28/38), 52.6% (20/38), 48.6% (17/35), and 13.2% (5/38) of study participants were HRP-2 positive on days 14, 28, 35, and 42, respectively, compared with 0%, 2.6% (1/38), 2.9% (1/35), and 2.6% (1/38) for LDH.

CONCLUSION:

The HRP2-based RDT fulfilled World Health Organization criteria for malaria diagnosis in patients with SCD and may provide diagnostic evidence for treatment to begin in cases in which treatment would otherwise have begun presumptively based on symptoms, whereas LDH-based RDTs may be more suitable as a confirmatory test in low-parasitemic subgroups, such as patients with SCD.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Malária Falciparum / Anemia Falciforme / Malária Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Child / Humans Idioma: En Revista: Clin Infect Dis Assunto da revista: DOENCAS TRANSMISSIVEIS Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Gana

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Malária Falciparum / Anemia Falciforme / Malária Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Child / Humans Idioma: En Revista: Clin Infect Dis Assunto da revista: DOENCAS TRANSMISSIVEIS Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Gana