A Comparison of EIS and QCM NanoMIP-Based Sensors for Morphine.
D'Aurelio, Roberta; Tothill, Ibtisam E; Salbini, Maria; Calò, Francesca; Mazzotta, Elisabetta; Malitesta, Cosimino; Chianella, Iva.
Afiliação
  • D'Aurelio R; Surface Engineering and Precision Centre, School of Aerospace, Transport and Manufacturing, Cranfield University, Cranfield, Bedford MK43 0AL, UK.
  • Tothill IE; Surface Engineering and Precision Centre, School of Aerospace, Transport and Manufacturing, Cranfield University, Cranfield, Bedford MK43 0AL, UK.
  • Salbini M; Surface Engineering and Precision Centre, School of Aerospace, Transport and Manufacturing, Cranfield University, Cranfield, Bedford MK43 0AL, UK.
  • Calò F; Laboratorio di Chimica Analitica, Edificio Multipiano CSEEM A6., Dipartimento di Scienze e Tecnologie Biologiche ed Ambientali, Università del Salento, I-73100 Lecce, Italy.
  • Mazzotta E; Surface Engineering and Precision Centre, School of Aerospace, Transport and Manufacturing, Cranfield University, Cranfield, Bedford MK43 0AL, UK.
  • Malitesta C; Laboratorio di Chimica Analitica, Edificio Multipiano CSEEM A6., Dipartimento di Scienze e Tecnologie Biologiche ed Ambientali, Università del Salento, I-73100 Lecce, Italy.
  • Chianella I; Laboratorio di Chimica Analitica, Edificio Multipiano CSEEM A6., Dipartimento di Scienze e Tecnologie Biologiche ed Ambientali, Università del Salento, I-73100 Lecce, Italy.
Nanomaterials (Basel) ; 11(12)2021 Dec 11.
Article em En | MEDLINE | ID: mdl-34947709
ABSTRACT
In this work we have compared two different sensing platforms for the detection of morphine as an example of a low molecular weight target analyte. For this, molecularly imprinted polymer nanoparticles (NanoMIP), synthesized with an affinity towards morphine, were attached to an electrochemical impedance spectroscopy (EIS) and a quartz crystal microbalance (QCM) sensor. Assay design, sensors fabrication, analyte sensitivity and specificity were performed using similar methods. The results showed that the EIS sensor achieved a limit of detection (LOD) of 0.11 ng·mL-1, which is three orders of magnitude lower than the 0.19 µg·mL-1 achieved using the QCM sensor. Both the EIS and the QCM sensors were found to be able to specifically detect morphine in a direct assay format. However, the QCM method required conjugation of gold nanoparticles (AuNPs) to the small analyte (morphine) to amplify the signal and achieve a LOD in the µg·mL-1 range. Conversely, the EIS sensor method was labor-intensive and required extensive data handling and processing, resulting in longer analysis times (~30-40 min). In addition, whereas the QCM enables visualization of the binding events between the target molecule and the sensor in real-time, the EIS method does not allow such a feature and measurements are taken post-binding. The work also highlighted the advantages of using QCM as an automated, rapid and multiplex sensor compared to the much simpler EIS platform used in this work, though, the QCM method will require sample preparation, especially when a sensitive (ng·mL-1) detection of a small analyte is needed.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Nanomaterials (Basel) Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Nanomaterials (Basel) Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Reino Unido