Your browser doesn't support javascript.
loading
Internal calibration as an emerging approach for endogenous analyte quantification: Application to steroids.
Visconti, Gioele; Olesti, Eulalia; González-Ruiz, Víctor; Glauser, Gaëtan; Tonoli, David; Lescuyer, Pierre; Vuilleumier, Nicolas; Rudaz, Serge.
Afiliação
  • Visconti G; School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland.
  • Olesti E; School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland; Swiss Centre for Applied Human Toxicology (SCAHT), S
  • González-Ruiz V; School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland; Swiss Centre for Applied Human Toxicology (SCAHT), S
  • Glauser G; Neuchâtel Platform of Analytical Chemistry, University of Neuchâtel, Avenue de Bellevaux 51, 2000 Neuchâtel, Switzerland.
  • Tonoli D; Division of Laboratory Medicine, Geneva University Hospitals (HUG), Geneva, Switzerland.
  • Lescuyer P; Division of Laboratory Medicine, Geneva University Hospitals (HUG), Geneva, Switzerland.
  • Vuilleumier N; Division of Laboratory Medicine, Geneva University Hospitals (HUG), Geneva, Switzerland.
  • Rudaz S; School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland; Swiss Centre for Applied Human Toxicology (SCAHT), S
Talanta ; 240: 123149, 2022 Apr 01.
Article em En | MEDLINE | ID: mdl-34954616
ABSTRACT
The use of mass spectrometry methods with triple quadrupole instruments is well established for quantification. However, the preparation of calibration curves can be time-consuming and prone to analytical errors. In this study, an innovative internal calibration (IC) approach using a one-standard calibration with a stable isotope-labeled (SIL) standard version of the endogenous compound was developed. To ensure optimal quantitative performance, the following parameters were evaluated the stability of the analyte-to-SIL response factor (RF), the chemical and isotopic purities of the SIL, and the instrumental reproducibility. Using six clinically important endogenous steroids and their respective SIL standards, we demonstrated that RFs obtained on different LC-MS platforms were consistent. The quantitative performance of the proposed approach was determined using quality control samples prepared in depleted serum, and showed both satisfactory precision (1.3%-12.4%) and trueness (77.5%-107.0%, with only 3 values outside ±30%). The developed method was then applied to human serum samples, and the results were similar to those obtained with the conventional quantification approach based on external calibration the Passing-Bablok regression showed a proportional bias of 6.8% and a mean difference of -5.9% between the two methodologies. Finally, we showed that the naturally occurring isotopes of the SIL can be used to provide additional calibration points and increase the accuracy for analytes with low concentrations.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Esteroides / Espectrometria de Massas em Tandem Tipo de estudo: Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: Talanta Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Esteroides / Espectrometria de Massas em Tandem Tipo de estudo: Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: Talanta Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Suíça