Mid-term results of arthroscopic Bankart repair and remplissage for recurrent anterior shoulder instability in patients with a history of seizures.
BMC Musculoskelet Disord
; 23(1): 12, 2022 Jan 03.
Article
em En
| MEDLINE
| ID: mdl-34980078
ABSTRACT
BACKGROUND:
Seizure predisposes patients to shoulder dislocation. However, there is no consensus regarding the best management approach for recurrent shoulder dislocation in patients who have a history of seizures. In this study, we report the outcome of arthroscopic Bankart repair augmented by Remplissage for the recurrent anterior shoulder dislocation in a series of patients with a history of seizures.METHODS:
In this retrospective study, 27 patients with 29 recurrent anterior shoulder dislocations who were treated with the arthroscopic Bankart repair were included. All cases had deep Hill-Sachs lesions according to Hardy classification that was managed with a Remplissage technique. Patients with a glenoid defect of more than 20% in the CT scan were excluded. Twenty-two patients had an epileptic seizure, while the remaining five patients had convulsions due to other causes. The mean age of the patients was 28.3 ± 6.2 years. The mean follow-up of the patients was 3.1 ± 1.2 years. Outcome measures included the shoulder range of motion that was compared with the non-injured side in the unilateral subjects and the shoulder function that was evaluated by the Rowe score and the Walch-Duplay score.RESULTS:
The mean forward flexion, abduction, external rotation, and internal rotation were not significantly different between injured and non-injured shoulder (p = 0.34, p = 0.41, p = 0.11, p = 0.23). The mean Rowe score was 49.1 ± 7.8 before the surgery and 92.1 ± 6.4 at the last visit (p < 0.001). According to the Walch-Duplay score, the shoulders were categorized as excellent, good, and fair in 17 (58.7%), 11 (37.9%), and 1 (3.4%) shoulder, respectively. The overall rate of instability recurrence was 17.2% (n = 5).CONCLUSION:
In patients with a history of seizures, arthroscopic Bankart repair augmented by Remplissage could be regarded as a safe and efficient method for the treatment of recurrent anterior shoulder dislocation with glenoid defect < 20%.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Luxação do Ombro
/
Articulação do Ombro
/
Instabilidade Articular
Tipo de estudo:
Observational_studies
Limite:
Adult
/
Humans
Idioma:
En
Revista:
BMC Musculoskelet Disord
Assunto da revista:
FISIOLOGIA
/
ORTOPEDIA
Ano de publicação:
2022
Tipo de documento:
Article
País de afiliação:
Irã