Your browser doesn't support javascript.
loading
Minimum 5-Year Outcomes of a Multicenter, Prospective, Randomized Control Trial Assessing Clinical and Radiological Outcomes of Patient-Specific Instrumentation in Total Knee Arthroplasty.
Hampton, Matthew J; Blakey, Caroline M; Anderson, Alex A; Tomouk, Wassim M; Buckley, Simon C; Hamer, Andrew J; Sutton, Paul M.
Afiliação
  • Hampton MJ; Department of Trauma and Orthopaedics, Northern General Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, South Yorkshire, United Kingdom.
  • Blakey CM; Department of Trauma and Orthopaedics, Sheffield Children's Hospital, Sheffield Children's NHS Foundation Trust, Sheffield, United Kingdom.
  • Anderson AA; Department of Trauma and Orthopaedics, Rotherham District General Hospital, The Rotherham NHS Foundation Trust, Rotherham, South Yorkshire, United Kingdom.
  • Tomouk WM; Department of Trauma and Orthopaedics, Northern General Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, South Yorkshire, United Kingdom.
  • Buckley SC; Department of Trauma and Orthopaedics, Northern General Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, South Yorkshire, United Kingdom.
  • Hamer AJ; Department of Trauma and Orthopaedics, Northern General Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, South Yorkshire, United Kingdom.
  • Sutton PM; Department of Trauma and Orthopaedics, Northern General Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, South Yorkshire, United Kingdom.
J Arthroplasty ; 37(8): 1579-1585, 2022 08.
Article em En | MEDLINE | ID: mdl-35077818
ABSTRACT

BACKGROUND:

Patient-specific instrumentation (PSI) was developed to produce more accurate alignment of components and consequently improve clinical outcomes when used in total knee arthroplasty. We compare radiological accuracy and clinical outcomes at a minimum of 5-year follow-up between patients randomized to undergo total knee arthroplasty performed using PSI or traditional cutting block techniques.

METHODS:

This multicenter, randomized control trial included patients blinded to the technique 1used. Outcome measures were coronal alignment measured radiologically, Euroqol-5D, Oxford knee score, and International Knee Society Score measured at 1- and 5-year follow-up.

RESULTS:

At a minimum 5-year follow-up, there were 38 knees in the PSI group and 39 in the conventional instrumentation group for analysis. Baseline demographics and clinical outcome scores were matched between groups. Overall, there was no significant difference in the coronal femoral angle (P = .59), coronal tibial angle (P = .37), tibiofemoral angle (P = .99), sagittal femoral angle (P = .34), or the posterior tibia slope (P = .12) between knees implanted using PSI and those implanted with traditional cutting blocks. On the measurement of coronal alignment, intraobserver reliability tests demonstrated substantial agreement (k = 0.64). Clinical outcomes at both 1-year and 5-year follow-up demonstrated statistically significant and clinically relevant improvement in scores from baseline in both groups, but no difference could be detected between the Euroqol-5D (P = .78), Oxford knee score (P = .24), or International Knee Society Score (P = .86) between the 2 groups.

CONCLUSION:

This study has shown no additional benefit to PSI in terms of improved alignment or functional outcomes at minimum 5-year follow-up over traditional techniques.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia do Joelho / Osteoartrite do Joelho / Cirurgia Assistida por Computador / Prótese do Joelho Tipo de estudo: Clinical_trials / Observational_studies Limite: Humans Idioma: En Revista: J Arthroplasty Assunto da revista: ORTOPEDIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia do Joelho / Osteoartrite do Joelho / Cirurgia Assistida por Computador / Prótese do Joelho Tipo de estudo: Clinical_trials / Observational_studies Limite: Humans Idioma: En Revista: J Arthroplasty Assunto da revista: ORTOPEDIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Reino Unido