The lateral entry point S2 alar-iliac (L-S2AI) screw: a preoperative computed tomography analysis of adult spinal deformity patients.
Hey, Hwee Weng Dennis; Ramos, Miguel Rafael David; Tay, Hui Wen; Lin, Shuxun; Liu, Ka-Po Gabriel; Wong, Hee-Kit.
Afiliação
  • Hey HWD; Department of Orthopaedic Sugery, National University Hospital, National University Health System, 1E Kent Ridge Road, NUHS Tower Block Level 11, Singapore, 119228, Singapore. doshhwd@nus.edu.sg.
  • Ramos MRD; Department of Orthopaedic Sugery, National University Hospital, National University Health System, 1E Kent Ridge Road, NUHS Tower Block Level 11, Singapore, 119228, Singapore.
  • Tay HW; Department of Orthopaedic Sugery, National University Hospital, National University Health System, 1E Kent Ridge Road, NUHS Tower Block Level 11, Singapore, 119228, Singapore.
  • Lin S; Department of Orthopaedic Sugery, National University Hospital, National University Health System, 1E Kent Ridge Road, NUHS Tower Block Level 11, Singapore, 119228, Singapore.
  • Liu KG; Department of Orthopaedic Sugery, National University Hospital, National University Health System, 1E Kent Ridge Road, NUHS Tower Block Level 11, Singapore, 119228, Singapore.
  • Wong HK; Department of Orthopaedic Sugery, National University Hospital, National University Health System, 1E Kent Ridge Road, NUHS Tower Block Level 11, Singapore, 119228, Singapore.
Spine Deform ; 10(3): 669-678, 2022 05.
Article em En | MEDLINE | ID: mdl-35088384
ABSTRACT

PURPOSE:

To radiographically compare lateral entry point S2-alar-iliac (L-S2AI) screw with conventional S2AI (C-S2AI) and conventional iliac screw (CIS) lengths and trajectories.

METHODS:

Twenty-five preoperative CT scans of consecutive patients undergoing adult spinal deformity realignment surgery over a random 2-year period were analysed. Maximum in-bone length, caudal and lateral trajectories of CIS, C-S2AI, and L-S2AI screws were measured and compared using One-way ANOVA with Tukey's post hoc tests. Multivariate logistic regression was performed to identify predictors of high screw length discrepancy between C-S2AI and L-S2AI.

RESULTS:

Potential screw length was longest for CIS, followed by L-S2AI, then C-S2AI (114.5 ± 8.3 mm vs 101.4 ± 9.6 mm vs 80.6 ± 5.9 mm, respectively) in all patients (p < 0.001). Actual screw lengths found both CIS and L-S2AI to be longer than C-S2AI (95.3 ± 8.5 mm and 93.4 ± 7.5 mm vs 82.1 ± 7.3 mm; p = 0.008 and 0.003). Potential lateral angulation was smallest for CIS, followed by L-S2AI, then C-S2AI (21.9 ± 7.0° vs 31.9 ± 7.1° vs 40.9 ± 6.7°, respectively) in all patients (p < 0.001). L-S2AI and C-S2AI had the same caudal angulation (24.9 ± 6.8°), which was smaller than CIS (30.8 ± 5.8°) in all patients (p < 0.001). Univariate, but not multivariate analysis, revealed that lumbar lordosis > 40° (OR 7.2, p = 0.041), diagnosis of degenerative spondylolisthesis (OR 10.5, p = 0.017), and > 7 instrumented levels (OR 2.6, p = 0.049) were significantly associated with high screw discrepancies.

CONCLUSION:

The L-S2AI screw combines advantages of CIS and C-S2AI screws, which includes increased screw length, reduced lateral angulation, a low-profile screw head, ease of connection to proximal hardware, and the biomechanical advantage of a quadcortical purchase.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sacro / Fusão Vertebral Limite: Adult / Humans Idioma: En Revista: Spine Deform Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Singapura

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sacro / Fusão Vertebral Limite: Adult / Humans Idioma: En Revista: Spine Deform Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Singapura