Your browser doesn't support javascript.
loading
Whole-brain mapping of mouse CSF flow via HEAP-METRIC phase-contrast MRI.
Li, Juchen; Pei, Mengchao; Bo, Binshi; Zhao, Xinxin; Cang, Jing; Fang, Fang; Liang, Zhifeng.
Afiliação
  • Li J; Department of Anesthesia, Zhongshan Hospital, Fudan University, Shanghai, People's Republic of China.
  • Pei M; Institute of Neuroscience, CAS Key Laboratory of Primate Neurobiology, Center for Excellence in Brain Science and Intelligence Technology, Chinese Academy of Sciences, Shanghai, People's Republic of China.
  • Bo B; Institute of Neuroscience, CAS Key Laboratory of Primate Neurobiology, Center for Excellence in Brain Science and Intelligence Technology, Chinese Academy of Sciences, Shanghai, People's Republic of China.
  • Zhao X; Institute of Neuroscience, CAS Key Laboratory of Primate Neurobiology, Center for Excellence in Brain Science and Intelligence Technology, Chinese Academy of Sciences, Shanghai, People's Republic of China.
  • Cang J; Department of Radiology, Shanghai Cancer Institute, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of China.
  • Fang F; Department of Anesthesia, Zhongshan Hospital, Fudan University, Shanghai, People's Republic of China.
  • Liang Z; Department of Anesthesia, Zhongshan Hospital, Fudan University, Shanghai, People's Republic of China.
Magn Reson Med ; 87(6): 2851-2861, 2022 06.
Article em En | MEDLINE | ID: mdl-35107833
ABSTRACT

PURPOSE:

CSF plays important roles in clearing brain waste and homeostasis. However, mapping whole-brain CSF flow in the rodents is difficult, primarily due to its assumed very low velocity. Therefore, we aimed to develop a novel phase-contrast MRI method to map whole-brain CSF flow in the mouse brain.

METHODS:

A novel generalized Hadamard encoding-based multi-band scheme (dubbed HEAP-METRIC, Hadamard Encoding APproach of Multi-band Excitation for short TR Imaging aCcelerating) using complex Hadamard matrix was developed and incorporated into conventional phase contrast (PC)-MRI to significantly increase SNR.

RESULTS:

Slow flow phantom imaging validated HEAP-METRIC PC-MRI's ability to achieve fast and accurate mapping of slow flow velocities (~102  µm/s). With the SNR gain afforded by HEAP-METRIC scheme, high-resolution (0.08 × 0.08 mm in-plane resolution and 36 0.4 mm slices) PC-MRI was completed in 21 min for whole-brain CSF flow mapping in the mouse. Using this novel method, we provide the first report of whole-brain CSF flow in the awake mouse brain with an average flow velocity of ~200 µm/s. Furthermore, HEAP-METRIC PC-MRI revealed CSF flow was reduced by isoflurane anesthesia, accompanied by reduction of glymphatic function as measured by dynamic contrast-enhanced MRI.

CONCLUSION:

We developed and validated a generalized HEAP-METRIC PC-MRI for mapping low velocity flow. With this method, we have achieved the first whole-brain mapping of awake mouse CSF flow and have further revealed that anesthesia reduces CSF flow velocity.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Isoflurano Limite: Animals Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Isoflurano Limite: Animals Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2022 Tipo de documento: Article