Your browser doesn't support javascript.
loading
Sequential injection spectrophotometric method for screening bromate produced as an ozonation water disinfection by-product.
Mesquita, Raquel B R; Ferreira, Francisca T S M; Cerqueira, Ana; Rangel, António O S S.
Afiliação
  • Mesquita RBR; CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Universidade Católica Portuguesa, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal. rmesquita@porto.ucp.pt.
  • Ferreira FTSM; CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Universidade Católica Portuguesa, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal.
  • Cerqueira A; CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Universidade Católica Portuguesa, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal.
  • Rangel AOSS; CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Universidade Católica Portuguesa, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal.
Anal Sci ; 38(1): 137-143, 2022 Jan.
Article em En | MEDLINE | ID: mdl-35287215
ABSTRACT
The aim of this work was the development of an automatic sequential injection analysis method to monitor the ozonation process for water disinfection. The determination was based on the reaction between bromate and o-dianisidine in the presence of bromide in acidic medium. The determination parameters were studied and adjusted to enable bromate quantification in the range 0.35-4.0 mg BrO3-/L with a limit of detection of 20 µg BrO3-/L. The choice of a sequential injection procedure enabled a minimal consumption of reagents and no need for sample pre-treatment. The developed sequential injection proved to be accurate with < 5% relative deviation when compared to ICP-MS and an average of 101% in recovery percentages studies. It was effectively applied to monitor an ozonation process enabling the follow-up of the process with real-time quantification of the bromate content.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ozônio / Bromatos Tipo de estudo: Diagnostic_studies / Screening_studies Idioma: En Revista: Anal Sci Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Portugal

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ozônio / Bromatos Tipo de estudo: Diagnostic_studies / Screening_studies Idioma: En Revista: Anal Sci Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Portugal