Your browser doesn't support javascript.
loading
Ultra-High-Throughput Ambient MS: Direct Analysis at 22 Samples per Second by Infrared Matrix-Assisted Laser Desorption Electrospray Ionization Mass Spectrometry.
Radosevich, Andrew J; Pu, Fan; Chang-Yen, David; Sawicki, James W; Talaty, Nari N; Elsen, Nathaniel L; Williams, Jon D; Pan, Jeffrey Y.
Afiliação
  • Radosevich AJ; AbbVie Inc., 1 North Waukegan Road, North Chicago, Illinois 60064, United States.
  • Pu F; AbbVie Inc., 1 North Waukegan Road, North Chicago, Illinois 60064, United States.
  • Chang-Yen D; AbbVie Inc., 1 North Waukegan Road, North Chicago, Illinois 60064, United States.
  • Sawicki JW; AbbVie Inc., 1 North Waukegan Road, North Chicago, Illinois 60064, United States.
  • Talaty NN; AbbVie Inc., 1 North Waukegan Road, North Chicago, Illinois 60064, United States.
  • Elsen NL; AbbVie Inc., 1 North Waukegan Road, North Chicago, Illinois 60064, United States.
  • Williams JD; AbbVie Inc., 1 North Waukegan Road, North Chicago, Illinois 60064, United States.
  • Pan JY; AbbVie Inc., 1 North Waukegan Road, North Chicago, Illinois 60064, United States.
Anal Chem ; 94(12): 4913-4918, 2022 03 29.
Article em En | MEDLINE | ID: mdl-35290016
Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) mass spectrometry is an ambient-direct sampling method that is being developed for high-throughput, label-free, biochemical screening of large-scale compound libraries. Here, we report the development of an ultra-high-throughput continuous motion IR-MALDESI sampling approach capable of acquiring data at rates up to 22.7 samples per second in a 384-well microtiter plate. At top speed, less than 1% analyte carryover is observed from well-to-well, and signal intensity relative standard deviations (RSD) of 11.5% and 20.9% for 3 µM 1-hydroxymidazolam and 12 µM dextrorphan, respectively, are achieved. The ability to perform parallel kinetics studies on 384 samples with a ∼30 s time resolution using an isocitrate dehydrogenase 1 (IDH1) enzyme assay is shown. Finally, we demonstrate the repeatability and throughput of our approach by measuring 115200 samples from 300 microtiter plate reads consecutively over 5.54 h with RSDs under 8.14% for each freshly introduced plate. Taken together, these results demonstrate the use of IR-MALDESI at sample acquisition rates that surpass other currently reported direct sampling mass spectrometry approaches used for high-throughput compound screening.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas por Ionização por Electrospray / Ensaios de Triagem em Larga Escala Idioma: En Revista: Anal Chem Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas por Ionização por Electrospray / Ensaios de Triagem em Larga Escala Idioma: En Revista: Anal Chem Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos