Your browser doesn't support javascript.
loading
Optical assay using B-doped core-shell Fe@BC nanozyme for determination of alanine aminotransferase.
Tian, Dazhi; Xiang, Wen; Wang, Hao; Jiang, Wentao; Li, Ting; Yang, Minghui.
Afiliação
  • Tian D; Key Laboratory of Transplantation, Chinese Academy of Medical Sciences, Beijing, 100730, China.
  • Xiang W; Tianjin Key Laboratory for Organ Transplantation, Department of Liver Transplantation, Tianjin First Center Hospital, Tianjin, 300192, China.
  • Wang H; Tianjin Key Laboratory for Organ Transplantation, Department of Liver Transplantation, Tianjin First Center Hospital, Tianjin, 300192, China.
  • Jiang W; Tianjin Key Laboratory for Organ Transplantation, Department of Liver Transplantation, Tianjin First Center Hospital, Tianjin, 300192, China.
  • Li T; Key Laboratory of Transplantation, Chinese Academy of Medical Sciences, Beijing, 100730, China. jiang-wentao@medmail.com.cn.
  • Yang M; Tianjin Key Laboratory for Organ Transplantation, Department of Liver Transplantation, Tianjin First Center Hospital, Tianjin, 300192, China. jiang-wentao@medmail.com.cn.
Mikrochim Acta ; 189(4): 147, 2022 03 17.
Article em En | MEDLINE | ID: mdl-35299258
ABSTRACT
B-doped core-shell Fe@BC nanozyme was synthesized. The peroxidase (POD) like activity of Fe@BC nanozyme was studied and utilized for detecting the activity of alanine aminotransferase (ALT). In the presence of ALT as well as ALT co-substrates L-alanine and α-ketoglutarate, L-glutamate is generated. The following catalytic oxidation of L-glutamate by glutamate oxidase leads to the generation of H2O2. The POD-like activity of Fe@BC can oxidize 3,3',5,5'-tetramethylbenzidine (TMB) to oxTMB in the presence of H2O2, generating a blue-colored compound. Through the detection of the amount of H2O2 generated, ALT activity can be determined through measuring the absorbance intensity variation at 450 nm. The limit of detection of the assay is 4 U/L, with a linear range from 10 to 1000 U/L. For human serum samples, the ALT levels determined by our assay are comparable to those determined by the hospital with a correlation coefficient of 0.991, demonstrating the reliability of our assay results.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Colorimetria / Alanina Transaminase Limite: Humans Idioma: En Revista: Mikrochim Acta Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China