Chemometrically Assisted Optimization of Pregabalin Fluorescent Derivatization Reaction with a Novel Xanthone Analogue and Validation of the Method for the Determination of Pregabalin in Bulk via a Plate Reader.
Kritikos, Nikolaos; Iliou, Aikaterini; Kalampaliki, Amalia D; Gikas, Evangelos; Kostakis, Ioannis K; Michel, Benoît Y; Dotsikas, Yannis.
Afiliação
  • Kritikos N; Laboratory of Pharmaceutical Analysis, Department of Pharmacy, National and Kapodistrian University of Athens, Panepistimioupoli Zografou, GR-157 71 Athens, Greece.
  • Iliou A; Laboratory of Pharmaceutical Analysis, Department of Pharmacy, National and Kapodistrian University of Athens, Panepistimioupoli Zografou, GR-157 71 Athens, Greece.
  • Kalampaliki AD; Division of Pharmaceutical Chemistry, Department of Pharmacy, National and Kapodistrian University of Athens, Panepistimioupoli Zografou, GR-157 71 Athens, Greece.
  • Gikas E; Laboratory of Analytical Chemistry, Department of Chemistry, National and Kapodistrian University of Athens, Panepistimioupoli Zografou, GR-157 71 Athens, Greece.
  • Kostakis IK; Division of Pharmaceutical Chemistry, Department of Pharmacy, National and Kapodistrian University of Athens, Panepistimioupoli Zografou, GR-157 71 Athens, Greece.
  • Michel BY; Institut de Chimie de Nice, CNRS, UMR 7272, Université Côte d'Azur, Parc Valrose, CEDEX 2, 06108 Nice, France.
  • Dotsikas Y; Laboratory of Pharmaceutical Analysis, Department of Pharmacy, National and Kapodistrian University of Athens, Panepistimioupoli Zografou, GR-157 71 Athens, Greece.
Molecules ; 27(6)2022 Mar 17.
Article em En | MEDLINE | ID: mdl-35335315
ABSTRACT
Quantitation of chromophore-free analytes is always a challenge. To this purpose, derivatization of the analyte constitutes a common strategy, leading to a product with a strong signal. In the current study, a novel xanthone analogue was utilized for the first time for the derivatization of pregabalin, a model analyte with a primary amine moiety that lacks a chromophore. The fact that only the xanthene-based derivative, formed after the derivatization reaction fluoresces, enables avoiding its chromatographic separation from the reagent and thus reducing the analysis time of a series of samples in 1-2 min via a plate reader. The reaction conditions were optimized via a central composite design (CCD), with fluorescence signal as the measure of the yield. The following factors that affect the derivatization reaction were chosen (a) temperature, (b) reaction time, and (c) triethylamine solution volume used to drive the reaction to completion. After the identification of the optimal conditions, the method was validated according to ICH guidelines, using a fluorescence plate reader for signal measurement (λex = 540, λem = 615 nm). Finally, the newly developed high-throughput method was applied to the determination of drug content in pregabalin bulk.