Your browser doesn't support javascript.
loading
Quantitative assessment of myelin density using [11C]MeDAS PET in patients with multiple sclerosis: a first-in-human study.
van der Weijden, Chris W J; Meilof, Jan F; van der Hoorn, Anouk; Zhu, Junqing; Wu, Chunying; Wang, Yanming; Willemsen, Antoon T M; Dierckx, Rudi A J O; Lammertsma, Adriaan A; de Vries, Erik F J.
Afiliação
  • van der Weijden CWJ; Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Hanzeplein 1, Groningen, The Netherlands.
  • Meilof JF; Department of Biomedical Sciences of Cells and Systems, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713GZ, Groningen, The Netherlands.
  • van der Hoorn A; Department of Neurology, Martini Ziekenhuis, Groningen, The Netherlands.
  • Zhu J; Radiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713GZ, Groningen, The Netherlands.
  • Wu C; Department of Radiology, Case Western Reserve University, Cleveland, OH, 44106, USA.
  • Wang Y; Department of Radiology, Case Western Reserve University, Cleveland, OH, 44106, USA.
  • Willemsen ATM; Department of Radiology, Case Western Reserve University, Cleveland, OH, 44106, USA.
  • Dierckx RAJO; Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Hanzeplein 1, Groningen, The Netherlands.
  • Lammertsma AA; Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Hanzeplein 1, Groningen, The Netherlands.
  • de Vries EFJ; Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Hanzeplein 1, Groningen, The Netherlands.
Eur J Nucl Med Mol Imaging ; 49(10): 3492-3507, 2022 08.
Article em En | MEDLINE | ID: mdl-35366079
ABSTRACT

PURPOSE:

Multiple sclerosis (MS) is a disease characterized by inflammatory demyelinated lesions. New treatment strategies are being developed to stimulate myelin repair. Quantitative myelin imaging could facilitate these developments. This first-in-man study aimed to evaluate [11C]MeDAS as a PET tracer for myelin imaging in humans.

METHODS:

Six healthy controls and 11 MS patients underwent MRI and dynamic [11C]MeDAS PET scanning with arterial sampling. Lesion detection and classification were performed on MRI. [11C]MeDAS time-activity curves of brain regions and MS lesions were fitted with various compartment models for the identification of the best model to describe [11C]MeDAS kinetics. Several simplified methods were compared to the optimal compartment model.

RESULTS:

Visual analysis of the fits of [11C]MeDAS time-activity curves showed no preference for irreversible (2T3k) or reversible (2T4k) two-tissue compartment model. Both volume of distribution and binding potential estimates showed a high degree of variability. As this was not the case for 2T3k-derived net influx rate (Ki), the 2T3k model was selected as the model of choice. Simplified methods, such as SUV and MLAIR2 correlated well with 2T3k-derived Ki, but SUV showed subject-dependent bias when compared to 2T3k. Both the 2T3k model and the simplified methods were able to differentiate not only between gray and white matter, but also between lesions with different myelin densities.

CONCLUSION:

[11C]MeDAS PET can be used for quantification of myelin density in MS patients and is able to distinguish differences in myelin density within MS lesions. The 2T3k model is the optimal compartment model and MLAIR2 is the best simplified method for quantification. TRIAL REGISTRATION NL7262. Registered 18 September 2018.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Substância Branca / Esclerose Múltipla Limite: Humans Idioma: En Revista: Eur J Nucl Med Mol Imaging Assunto da revista: MEDICINA NUCLEAR Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Substância Branca / Esclerose Múltipla Limite: Humans Idioma: En Revista: Eur J Nucl Med Mol Imaging Assunto da revista: MEDICINA NUCLEAR Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Holanda