Prussian blue-modified laser-induced graphene platforms for detection of hydrogen peroxide.
Matias, Tiago A; de Faria, Lucas V; Rocha, Raquel G; Silva, Murillo N T; Nossol, Edson; Richter, Eduardo M; Muñoz, Rodrigo A A.
Afiliação
  • Matias TA; Center for Research On Electroanalysis, Institute of Chemistry, Federal University of Uberlândia, Uberlandia, MG, 38408-100, Brazil.
  • de Faria LV; Center for Research On Electroanalysis, Institute of Chemistry, Federal University of Uberlândia, Uberlandia, MG, 38408-100, Brazil.
  • Rocha RG; Center for Research On Electroanalysis, Institute of Chemistry, Federal University of Uberlândia, Uberlandia, MG, 38408-100, Brazil.
  • Silva MNT; Institute of Chemistry, Federal University of Uberlândia, Uberlandia, MG, 38408-100, Brazil.
  • Nossol E; Institute of Chemistry, Federal University of Uberlândia, Uberlandia, MG, 38408-100, Brazil.
  • Richter EM; Center for Research On Electroanalysis, Institute of Chemistry, Federal University of Uberlândia, Uberlandia, MG, 38408-100, Brazil.
  • Muñoz RAA; Center for Research On Electroanalysis, Institute of Chemistry, Federal University of Uberlândia, Uberlandia, MG, 38408-100, Brazil. munoz@ufu.br.
Mikrochim Acta ; 189(5): 188, 2022 04 11.
Article em En | MEDLINE | ID: mdl-35404013
ABSTRACT
A laser-induced graphene (LIG) surface modified with Prussian blue (iron hexacyanoferrate) is demonstrated as a novel electrochemical sensing platform for the sensitive and selective detection of hydrogen peroxide. Electrochemical Prussian blue (PB) modification on porous graphene films engraved by infrared laser over flexible polyimide was accomplished. Scanning electron microscopy images combined with Raman spectra confirm the formation of porous graphene and homogenous electrodeposition of PB over this porous surface. Electrochemical impedance spectroscopy reveals a substantial decrease in the resistance to charge transfer values (from 395 to 31.4 Ω) after the PB insertion, which confirms the formation of a highly conductive PB-graphene composite. The synergistic properties of PB and porous graphene were investigated for the constant monitoring of hydrogen peroxide at 0.0 V vs. Ag|AgCl|KCl(sat.), under high-flow injections (166 µL s-1) confirming the high stability of the modified surface and fast response within a wide linear range (from 1 to 200 µmol L-1). Satisfactory detection limit (0.26 µmol L-1) and selectivity verified by the analysis of complex samples confirmed the excellent sensing performance of this platform. We highlight that the outstanding sensing characteristics of the developed sensor were superior in comparison with other PB-based or LIG-based electrochemical sensors reported for hydrogen peroxide detection.