Your browser doesn't support javascript.
loading
A Rapid LC-MS/MS-PRM Assay for Serologic Quantification of Sialylated O-HPX Glycoforms in Patients with Liver Fibrosis.
Panigrahi, Aswini; Benicky, Julius; Wei, Renhuizi; Ahn, Jaeil; Goldman, Radoslav; Sanda, Miloslav.
Afiliação
  • Panigrahi A; Lombardi Comprehensive Cancer Center, Department of Oncology, Georgetown University, Washington, DC 20057, USA.
  • Benicky J; Clinical and Translational Glycoscience Research Center, Georgetown University Medical Center, Georgetown University, Washington, DC 20057, USA.
  • Wei R; Lombardi Comprehensive Cancer Center, Department of Oncology, Georgetown University, Washington, DC 20057, USA.
  • Ahn J; Clinical and Translational Glycoscience Research Center, Georgetown University Medical Center, Georgetown University, Washington, DC 20057, USA.
  • Goldman R; Lombardi Comprehensive Cancer Center, Department of Oncology, Georgetown University, Washington, DC 20057, USA.
  • Sanda M; Clinical and Translational Glycoscience Research Center, Georgetown University Medical Center, Georgetown University, Washington, DC 20057, USA.
Molecules ; 27(7)2022 Mar 29.
Article em En | MEDLINE | ID: mdl-35408612
ABSTRACT
Development of high throughput robust methods is a prerequisite for a successful clinical use of LC-MS/MS assays. In earlier studies, we reported that nLC-MS/MS measurement of the O-glycoforms of HPX is an indicator of liver fibrosis. In this study, we show that a microflow LC-MS/MS method using a single column setup for capture of the analytes, desalting, fast gradient elution, and on-line mass spectrometry measurements, is robust, substantially faster, and even more sensitive than our nLC setup. We demonstrate applicability of the workflow on the quantification of the O-HPX glycoforms in unfractionated serum samples of control and liver disease patients. The assay requires microliter volumes of serum samples, and the platform is amenable to one hundred sample injections per day, providing a valuable tool for biomarker validation and screening studies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas em Tandem / Hepatopatias Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Molecules Assunto da revista: BIOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas em Tandem / Hepatopatias Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Molecules Assunto da revista: BIOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos