Your browser doesn't support javascript.
loading
The Relationship Between Inter-canthal Distance and Implant Height in Asian Rhinoplasty.
Huang, Chih-Jung; Yen, Cheng-I; Chang, Chun-Shin; Chen, Hung-Chang; Hsiao, Yen-Chang.
Afiliação
  • Huang CJ; Department of Plastic and Reconstruction Surgery, Linkou Chang Gung Memorial Hospital, Chang Gung University, 5, Fu-Hsing Street, Kweishan, Taoyuan City, 333, Taiwan, R.O.C.
  • Yen CI; Department of Plastic and Reconstruction Surgery, Linkou Chang Gung Memorial Hospital, Chang Gung University, 5, Fu-Hsing Street, Kweishan, Taoyuan City, 333, Taiwan, R.O.C.
  • Chang CS; Department of Plastic and Reconstruction Surgery, Linkou Chang Gung Memorial Hospital, Chang Gung University, 5, Fu-Hsing Street, Kweishan, Taoyuan City, 333, Taiwan, R.O.C.
  • Chen HC; Department of Plastic and Reconstruction Surgery, Linkou Chang Gung Memorial Hospital, Chang Gung University, 5, Fu-Hsing Street, Kweishan, Taoyuan City, 333, Taiwan, R.O.C.
  • Hsiao YC; Department of Plastic and Reconstruction Surgery, Linkou Chang Gung Memorial Hospital, Chang Gung University, 5, Fu-Hsing Street, Kweishan, Taoyuan City, 333, Taiwan, R.O.C.. nosehsiao@gmail.com.
Aesthetic Plast Surg ; 46(4): 1809-1815, 2022 08.
Article em En | MEDLINE | ID: mdl-35449422
ABSTRACT
Augmentation rhinoplasty is one of the top three anesthetic surgeries in Asia. I-shaped silicone-polytetrafluoroethylene composite implants are feasible for both primary and secondary augmentation rhinoplasty in Asians. This series was to analyze and evaluated the effect of the rhinoplasty to the intercanthal distance and to compare the height of the implantation with those differences in ICD before and after rhinoplasty. We retrospectively reviewed data from a single medical center via a single surgeon (Hsiao YC), at Chang Gung Memorial Hospital, between 2011 and 2017 with follow-up through 2018. There were 223 patients who received augmentation rhinoplasty with an I-shaped composite silicone-polytetrafluoroethylene ePTFE-lined silicone dorsal composite implant (Implantech, Ventura, CA) with a glabellar component (chimeric technique) or without a glabellar component. There were 169 patients with the height of the I-shaped composite implant over 3 mm, and 15 patients were less than 3 mm. There was no distribution significance between two groups even in gender, age, type of surgery, or indication. The paired difference of ICD/IPD ratio was statistically significant in the group with the height of composite implant over 3 mm (1.04% ± 0.11, p < 0.005, 95%). The normalized ratio of the ICD to IPD is estimated to decrease by 1-2%. Appropriate candidates including those with a wide ICD should be informed about these data during preoperative decision-making.Level of Evidence V This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Rinoplastia Tipo de estudo: Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Aesthetic Plast Surg Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Rinoplastia Tipo de estudo: Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Aesthetic Plast Surg Ano de publicação: 2022 Tipo de documento: Article