Your browser doesn't support javascript.
loading
Assessment and treatment of floodwater in the Vietnamese Mekong Delta using a simple filter system based on silver nanoparticles coated onto activated carbon derived from rice husk.
Dao, My Uyen; Hoang, Hien Y; Tran, Anh Khoa; Cong, Hong Hanh.
Afiliação
  • Dao MU; Center for Advanced Chemistry, Institute of Research & Development, Duy Tan University Danang 550000 Vietnam.
  • Hoang HY; Faculty of Natural Sciences, Duy Tan University Danang 550000 Vietnam.
  • Tran AK; Faculty of Environment, Ho Chi Minh City University of Natural Resources and Environment Ho Chi Minh City 70000 Vietnam hhy@hcmunre.edu.vn.
  • Cong HH; Faculty of Environment, Ho Chi Minh City University of Natural Resources and Environment Ho Chi Minh City 70000 Vietnam hhy@hcmunre.edu.vn.
RSC Adv ; 11(63): 39838-39847, 2021 Dec 13.
Article em En | MEDLINE | ID: mdl-35494158
ABSTRACT
The floods in the Vietnamese Mekong Delta have long caused a shortage of clean water supply, which has a significant impact on the indigenous people in the region. We have conducted a preliminary survey of the water quality of the Hau Giang River (one of the two main branches of the Mekong River) before, during, and after the flood season. The obtained results demonstrated that the water in the Hau Giang River was highly turbid and contaminated with a large number of harmful microorganisms. Thus, in this study, a simple filter system based on silver nanoparticles coated onto activated carbon derived from rice husk (AgNPs@AC) has been proposed for treating floodwater from the Hau Giang River. The optimal conditions for AgNPs@AC preparation were established. The prepared AgNPs@AC was then characterized using various surface analyses such as SEM, TEM, XRD, BET, FTIR, and DLS. The initial floodwater source would be pre-treated with polyaluminum chloride using the coagulation-sedimentation method to remove the suspended solids before being discharged into the filtration column containing AgNPs@AC. The results showed that the filter system based on AgNPs@AC performed well in removing turbidity, dissolved solids, suspended solids, color, and bacteria from the floodwater. In addition, it was determined that the filter column with a 30 mm thick AgNPs@AC layer could continuously process 1300 m3 of the floodwater and had a service life of more than two months. The findings of this study not only added to our understanding of the floodwater treatment capacity of activated carbon coated nanoparticles, but they also provided valuable information for water treatment plants along the Hau Giang River, aquatic ecosystem researchers, and public health researchers.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: RSC Adv Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: RSC Adv Ano de publicação: 2021 Tipo de documento: Article