Your browser doesn't support javascript.
loading
Plasmonic features of free-standing chitosan nanocomposite film with silver and graphene oxide for SERS applications.
Samodelova, Mariia V; Kapitanova, Olesya O; Evdokimov, Pavel V; Eremina, Olga E; Goodilin, Eugene A; Veselova, Irina A.
Afiliação
  • Samodelova MV; Faculty of Chemistry, Lomonosov Moscow State University, Leninskie gory 1, Moscow, 119991, Russia.
  • Kapitanova OO; Faculty of Chemistry, Lomonosov Moscow State University, Leninskie gory 1, Moscow, 119991, Russia.
  • Evdokimov PV; Center for photonics and 2D materials, Moscow Institute of Physics and Technology, 9 Institutskiy per., Dolgoprudny, Moscow Region, 141701, Russia.
  • Eremina OE; Faculty of Chemistry, Lomonosov Moscow State University, Leninskie gory 1, Moscow, 119991, Russia.
  • Goodilin EA; Kurnakov Institute of General and Inorganic Chemistry of the Russian Academy of Sciences, Leninskii prospect 31, Moscow, 119991, Russia.
  • Veselova IA; Faculty of Chemistry, Lomonosov Moscow State University, Leninskie gory 1, Moscow, 119991, Russia.
Nanotechnology ; 33(33)2022 May 25.
Article em En | MEDLINE | ID: mdl-35508104
A scalable procedure of SERS substrates design was developed using a novel plasmonic structure based on a freestanding chitosan film, silver nanoparticles, and graphene oxide. Chitosan provides a uniform distribution of silver nanoparticles from a colloidal suspension and, therefore, a reproducible Raman signal from local areas of measurements of several tens of microns. The addition of graphene oxide (GO) to the colloidal solution of silver nanoparticles suppresses the tortuous background fluorescence signal from the analyte and leads to an increase in the signal-to-fluorescence background intensity ratio by up to 6 times as compared to structures without GO. The manufactured plasmonic polymer nanocomposite provides a detection limit of down to 100 pM for R6G using a laser wavelength of 532 nm through a portable ×10 objective. The high colloidal stability of GO in water and the use of an aqueous colloid of silver nanoparticles simplify the procedure for creating a substrate by applying the GO-silver composite on the surface of a chitosan film without a need to form a GO film. Therefore, our approach paves a promising avenue to provide more sensitive detection even for the fluorescent analytes with short-wavelength lasers (532, 633 nm) instead of IR (785, 1024 nm) and foster the practical application of the developed plasmonic composites on portable Raman spectrometers.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Nanotechnology Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Federação Russa

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Nanotechnology Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Federação Russa