Your browser doesn't support javascript.
loading
Investigation of the Association between Surgeon Sex and Laparoscopic Device Ergonomic Strain in Gynecologic Surgery.
Wong, Jacqueline M K; Moore, Kristin J; Carey, Erin T.
Afiliação
  • Wong JMK; Department of Obstetrics and Gynecology, Oregon Health and Science University, Portland, Oregon. Electronic address: wongjac@ohsu.edu.
  • Moore KJ; Department of Obstetrics and Gynecology, University of North Carolina, Chapel Hill, North Carolina.
  • Carey ET; Department of Obstetrics and Gynecology, University of North Carolina, Chapel Hill, North Carolina.
J Minim Invasive Gynecol ; 29(8): 984-991, 2022 08.
Article em En | MEDLINE | ID: mdl-35513300
ABSTRACT
STUDY

OBJECTIVE:

To assess whether female compared with male sex is associated with greater ergonomic strain with the use of 4 advanced energy laparoscopic devices (LigaSure, HALO PKS, ENSEAL, and Harmonic scalpel).

DESIGN:

Online survey distributed by e-mail using the REDCap platform (Vanderbilt University). All responses were anonymous.

SETTING:

Nationwide survey in the United States.

PARTICIPANTS:

Gynecologic surgeons were surveyed through the Society of Gynecologic Surgeons listserv and 4 obstetrics and gynecology departmental listservs.

INTERVENTIONS:

The survey was distributed between May 1, 2020, and November 1, 2020. The primary outcome was the presence of physical complaints owing to laparoscopic devices. Descriptive statistics compared surgeon characteristics and ergonomic symptoms. Logistic regression was performed, adjusted for surgeon characteristics. MEASUREMENTS AND MAIN

RESULTS:

The response rate was 39%, comprising 149 women (78%) and 41 men (22%). Women compared with men had a significantly younger age (mean, 34 vs 44 years; p <.01), had smaller glove size (mean, 6.5 vs 7.5; p <.01), had shorter height (median, 66 vs 71 inches; p <.01), and were less frequently in practice for >10 years (19% vs 49%; p <.01). Women significantly more often reported physical complaints related to the use of laparoscopic devices (79% vs 41%; p <.01). Women reported that all devices had too large a fit for appropriate use (p <.01). Women were found to have 5.37 times the odds of physical complaints attributed to the use of laparoscopic instruments (crude oods ratio, 5.37; 95% confidence interval, 2.56-11.25); with adjustment for glove size, age, and laparoscopic case volume and duration, this was no longer significant (adjusted odds ratio, 2.02; 95% confidence interval, 0.59-6.93).

CONCLUSION:

Women significantly more often report physical complaints and inappropriate fit of the LigaSure, HALO PKS, ENSEAL, and Harmonic scalpel. Female sex is associated with 5-fold greater odds of physical complaints with laparoscopic device use. Further investigation of the surgeon factors underlying device-related strain is a critical next step to understanding and reducing surgeon ergonomic injury.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Laparoscopia / Cirurgiões Tipo de estudo: Risk_factors_studies Limite: Adult / Female / Humans / Male País/Região como assunto: America do norte Idioma: En Revista: J Minim Invasive Gynecol Assunto da revista: GINECOLOGIA Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Laparoscopia / Cirurgiões Tipo de estudo: Risk_factors_studies Limite: Adult / Female / Humans / Male País/Região como assunto: America do norte Idioma: En Revista: J Minim Invasive Gynecol Assunto da revista: GINECOLOGIA Ano de publicação: 2022 Tipo de documento: Article