Your browser doesn't support javascript.
loading
A novel tool for motion-related dose inaccuracies reduction in 99mTc-MAA SPECT/CT images for SIRT planning.
Santoro, Miriam; Della Gala, Giuseppe; Paolani, Giulia; Zagni, Federico; Strolin, Silvia; Civollani, Simona; Calderoni, Letizia; Cappelli, Alberta; Mosconi, Cristina; Lodi Rizzini, Elisa; Tabacchi, Elena; Morganti, Alessio Giuseppe; Fanti, Stefano; Golfieri, Rita; Strigari, Lidia.
Afiliação
  • Santoro M; Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
  • Della Gala G; Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
  • Paolani G; Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
  • Zagni F; Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
  • Strolin S; Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
  • Civollani S; Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
  • Calderoni L; Nuclear Medicine Unit, IRCCS Azienda Ospedaliero, University of Bologna, 40138 Bologna, Italy.
  • Cappelli A; Department of Radiology, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
  • Mosconi C; Department of Radiology, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
  • Lodi Rizzini E; Radiation Oncology, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
  • Tabacchi E; Nuclear Medicine Unit, IRCCS Azienda Ospedaliero, University of Bologna, 40138 Bologna, Italy.
  • Morganti AG; Radiation Oncology, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
  • Fanti S; Nuclear Medicine Unit, IRCCS Azienda Ospedaliero, University of Bologna, 40138 Bologna, Italy.
  • Golfieri R; Department of Radiology, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
  • Strigari L; Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy. Electronic address: lidia.strigari@aosp.bo.it.
Phys Med ; 98: 98-112, 2022 Jun.
Article em En | MEDLINE | ID: mdl-35526374
ABSTRACT

INTRODUCTION:

In Selective Internal Radiation Therapy (SIRT), 90Y is administered to primary/secondary hepatic lesions. An accurate pre-treatment planning using 99mTc-MAA SPECT/CT allows the assessment of its feasibility and of the activity to be injected. Unfortunately, SPECT/CT suffers from patient-specific respiratory motion which causes artifacts and absorbed dose inaccuracies. In this study, a data-driven solution was developed to correct the respiratory motion.

METHODS:

The tool realigns the barycenter of SPECT projection images and shifts them to obtain a fine registration with the attenuation map. The tool was validated using a modified dynamic phantom with several breathing patterns. We compared the absorbed dose distributions derived from uncorrected(Dm)/corrected(Dc) images with static ones(Ds) in terms of γ-passing rates, 210 Gy isodose volumes, dose-volume histograms and percentage differences of mean doses (i.e., ΔD¯m and ΔD¯c, respectively). The tool was applied to twelve SIRT patients and the Bland-Altman analysis was performed on mean doses.

RESULTS:

In the phantom study, the agreement between Dc and Ds was higher (γ-passing rates generally > 90%) than Dm and Ds. The isodose volumes in Dc were closer than Dm to Ds, with differences up to 10% and 30% respectively. A reduction from a median ΔD¯m = -19.3% to ΔD¯c = -0.9%, from ΔD¯m = -42.8% to ΔD¯c = -7.0% and from ΔD¯m = 1586% to ΔD¯c = 47.2% was observed in liver-, tumor- and lungs-like structures. The Bland-Altman analysis on patients showed variations (±50 Gy) and (±4 Gy) between D¯c and D¯m of tumor and lungs, respectively.

CONCLUSION:

The proposed tool allowed the correction of 99mTc-MAA SPECT/CT images, improving the accuracy of the absorbed dose distribution.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radioterapia / Neoplasias Hepáticas Limite: Humans Idioma: En Revista: Phys Med Assunto da revista: BIOFISICA / BIOLOGIA / MEDICINA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radioterapia / Neoplasias Hepáticas Limite: Humans Idioma: En Revista: Phys Med Assunto da revista: BIOFISICA / BIOLOGIA / MEDICINA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Itália