Gas exchange analysers exhibit large measurement error driven by internal thermal gradients.
Garen, Josef C; Branch, Haley A; Borrego, Isaac; Blonder, Benjamin; Stinziano, Joseph R; Michaletz, Sean T.
Afiliação
  • Garen JC; Department of Botany and Biodiversity Research Centre, University of British Columbia, Vancouver, BC, V6T 1Z4, Canada.
  • Branch HA; Department of Botany and Biodiversity Research Centre, University of British Columbia, Vancouver, BC, V6T 1Z4, Canada.
  • Borrego I; Department of Botany and Biodiversity Research Centre, University of British Columbia, Vancouver, BC, V6T 1Z4, Canada.
  • Blonder B; Department of Environmental Science, Policy, and Management, University of California, Berkeley, CA, 94720, USA.
  • Stinziano JR; Canadian Food Inspection Agency, Ottawa, ON, K1A 0Y9, Canada.
  • Michaletz ST; Department of Botany and Biodiversity Research Centre, University of British Columbia, Vancouver, BC, V6T 1Z4, Canada.
New Phytol ; 236(2): 369-384, 2022 10.
Article em En | MEDLINE | ID: mdl-35762843
Portable gas exchange analysers provide critical data for understanding plant-atmosphere carbon and water fluxes, and for parameterising Earth system models that forecast climate change effects and feedbacks. We characterised temperature measurement errors in the Li-Cor LI-6400XT and LI-6800, and estimated downstream errors in derived quantities, including stomatal conductance (gsw ) and leaf intercellular CO2 concentration (Ci ). The LI-6400XT exhibited air temperature errors (differences between reported air temperature and air temperature measured near the leaf) up to 7.2°C, leaf temperature errors up to 5.3°C, and relative errors in gsw and Ci that increased as temperatures departed from ambient. This caused errors in leaf-to-air temperature relationships, assimilation-temperature curves and CO2 response curves. Temperature dependencies of maximum Rubisco carboxylation rate (Vcmax ) and maximum RuBP regeneration rate (Jmax ) showed errors of 12% and 35%, respectively. These errors are likely to be idiosyncratic and may differ among machines and environmental conditions. The LI-6800 exhibited much smaller errors. Earth system model predictions may be erroneous, as much of their parametrisation data were measured on the LI-6400XT system, depending on the methods used. We make recommendations for minimising errors and correcting data in the LI-6400XT. We also recommend transitioning to the LI-6800 for future data collection.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fotossíntese / Ribulose-Bifosfato Carboxilase Tipo de estudo: Prognostic_studies Idioma: En Revista: New Phytol Assunto da revista: BOTANICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fotossíntese / Ribulose-Bifosfato Carboxilase Tipo de estudo: Prognostic_studies Idioma: En Revista: New Phytol Assunto da revista: BOTANICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Canadá