Your browser doesn't support javascript.
loading
Safety and feasibility of a modularized procedure for trans-subxiphoid robotic extended thymectomy.
Zhang, Hanlu; Wang, Fuqiang; Qiu, Guanghao; Li, Zhiyang; Peng, Lei; Wang, Xuyang; Xie, Shenglong; Chen, Long-Qi; Wang, Yun.
Afiliação
  • Zhang H; Department of Thoracic Surgery, West China Hospital, Sichuan University, No. 37, Guoxue Alley, Chengdu, 610041, China.
  • Wang F; Department of Thoracic Surgery, West China Hospital, Sichuan University, No. 37, Guoxue Alley, Chengdu, 610041, China.
  • Qiu G; Department of Thoracic Surgery, West China Hospital, Sichuan University, No. 37, Guoxue Alley, Chengdu, 610041, China.
  • Li Z; Department of Thoracic Surgery, West China Hospital, Sichuan University, No. 37, Guoxue Alley, Chengdu, 610041, China.
  • Peng L; Department of Thoracic Surgery, West China Hospital, Sichuan University, No. 37, Guoxue Alley, Chengdu, 610041, China.
  • Wang X; Department of Thoracic Surgery, West China Hospital, Sichuan University, No. 37, Guoxue Alley, Chengdu, 610041, China.
  • Xie S; Department of Thoracic Surgery, West China Hospital, Sichuan University, No. 37, Guoxue Alley, Chengdu, 610041, China.
  • Chen LQ; Department of Thoracic Surgery, Hospital of the University of Electronic Science and Technology of China and Sichuan Provincial People's Hospital, Chengdu, China.
  • Wang Y; Department of Thoracic Surgery, West China Hospital, Sichuan University, No. 37, Guoxue Alley, Chengdu, 610041, China.
Surg Endosc ; 37(1): 90-100, 2023 01.
Article em En | MEDLINE | ID: mdl-35836034
ABSTRACT

BACKGROUND:

The purpose of this study was to introduce an "eight-step modularized procedure (M-RET)" for trans-subxiphoid robotic extended thymectomy for patients with myasthenia gravis (MG). Its safety and feasibility were further verified in this study. MATERIALS AND

METHODS:

This retrospective study included 87 consecutive MG patients who underwent trans-subxiphoid robotic extended thymectomy at our institution between September 2016 and August 2021. According to different resection models, patients were divided into two groups traditional trans-subxiphoid robotic extended thymectomy group (T-RET group) and eight-step modularized technique group (M-RET group). Baseline demographic characteristics and operation-related parameters were collected and compared between the two groups.

RESULTS:

There were 41 (47.1%) patients in the M-RET group and 46 (52.9%) patients in the T-RET group. The M-RET group resected a greater amount of mediastinal adipose tissues and required more dissection time (median and interquartile range 135.0, 125.0 to 164.0 v. 120.0, 105.0 to 153.8, P = 0.006) compared with the T-RET group. There were no statistically significant differences in terms of the intraoperative blood loss, duration of chest drainage, length of hospital stay, and postoperative complications between the two groups. There was no mortality or conversion in each of the two groups and all patients recovered well upon discharge.

CONCLUSION:

The eight-step modularized technique of trans-subxiphoid robotic extended thymectomy was verified to be a safe, effective, radical procedure, which offers unique superiority over ectopic thymic tissue resection.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimentos Cirúrgicos Robóticos / Miastenia Gravis Tipo de estudo: Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Surg Endosc Assunto da revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimentos Cirúrgicos Robóticos / Miastenia Gravis Tipo de estudo: Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Surg Endosc Assunto da revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China